Literature DB >> 26332422

Comparison of white blood cell counts by WNR, WDF, and WPC channels in Sysmex XN hematology analyzer.

H Kim1, M Hur1, S-G Choi1, K-M Oh2, H-W Moon1, Y-M Yun1.   

Abstract

INTRODUCTION: The Sysmex XN modular system (Sysmex, Kobe, Japan) uses a novel technology for white blood cell (WBC) count and differential, using separate channels: white cell nucleated (WNR), WBC differential (WDF), and white progenitor cell (WPC) channels. We questioned how concordant WBC counts would be between them.
METHODS: In a total of 6327 consecutive specimens, WBC counts were compared between WNR and WDF channels. They were also compared in three groups of WBC counts and two groups of chemotherapy status. In 508 specimens from the 4361 specimens that were run on the XN-20 module, the WPC channel was used for reflex test. Data were compared using Pearson's correlation, absolute difference, and percent difference (%D).
RESULTS: WBC counts between WNR and WDF channels showed very high correlations in total specimens (r = 0.9976) and in the groups of WBC counts and chemotherapy. As WBC count increased, absolute difference increased, while %D decreased (P < 0.0001, both). Percent difference was 1.55% in total specimens and showed the highest value in the severe leukopenia group (<1.0 × 10(9)/L, 6.18%).
CONCLUSIONS: This is the first large-scale study on novel channel technology for WBC counts in the Sysmex XN. WBC counts by WNR, WDF, and WPC channels are highly correlated, and they are overall interchangeable and reliable.
© 2015 John Wiley & Sons Ltd.

Entities:  

Keywords:  Sysmex XN; WNR, WDF, WPC, channel; comparison; white blood cells

Mesh:

Year:  2015        PMID: 26332422     DOI: 10.1111/ijlh.12421

Source DB:  PubMed          Journal:  Int J Lab Hematol        ISSN: 1751-5521            Impact factor:   2.877


  3 in total

1.  The Negative Predictive Ability of Immature Neutrophils for Bacteremia in Children With Community-Acquired Infections.

Authors:  Alexandre M Pimentel; Caroline C Vilas-Boas; Ticiana S Vilar; Cristiana M Nascimento-Carvalho
Journal:  Front Pediatr       Date:  2020-05-06       Impact factor: 3.418

2.  NEUT-SFL in Patients with COVID-ARDS: A Novel Biomarker for Thrombotic Events?

Authors:  Laure Stiel; Yannick Rabouel; Agathe Debliquis; Valentin Pointurier; Joy Mootien; Khaldoun Kuteifan
Journal:  Dis Markers       Date:  2021-11-17       Impact factor: 3.434

3.  Performance evaluation of routine blood and C-reactive protein analysis using Mindray BC-7500 CRP auto hematology analyzer.

Authors:  Zhen Lin; Qiu Lin; Pingli Yu; Zhixin Chen; Haifeng Lin; Bin Zhu; Meihua Wang; Yingping Cao
Journal:  Ann Transl Med       Date:  2022-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.