Literature DB >> 26332031

Real-time ultrasound-guided placement of a pigtail catheter in supine position for draining pleural effusion in pediatric patients who have undergone liver transplantation.

Roberto Miraglia1, Luigi Maruzzelli1, Marcello Piazza2, Giuseppe Gallo1, Mario D'Amico1, Marco Spada3, Patrizio Vitulo4, Angelo Luca1.   

Abstract

PURPOSE: Ultrasound (US) guidance is currently used for placement of wire-guided thoracic drains, and its use is associated with a decreased risk of complications. However, most studies conducted to date in this field have been performed on adult patients. The aim of this study was to report the technical success and complication rates observed during real-time US-guided placement of a thoracic pigtail catheter in pediatric liver-transplant recipients with symptomatic pleural effusion.
METHODS: This was a single-center retrospective review of the clinical records and images from pediatric liver-transplant patients with symptomatic pleural effusion who had undergone real-time US-guided pleural-space puncture followed by placement (via the Seldinger technique) of a pigtail catheter for drainage, between May 2006 and June 2014.
RESULTS: We identified 25 patients who had undergone 41 pigtail catheter-placement procedures during the study period. The patients' mean age (± SD) was 4.2 ± 3.9 years (range, 2 months to 16 years), and their mean weight was 14.2 ± 7.2 kg (range, 4.5-33 kg). Seventeen procedures had been performed in the intensive care unit, and 8, in patients undergoing mechanical ventilation. Twelve of the 41 procedures had been performed in patients with altered hemostasis (ie, platelet count < 50 × 10(3) /μl and/or international normalized ratio > 1.5). The size of the pigtail catheters ranged from 5 F to 8.5 F. The technical success rate was 100%, with no major complications such as pneumothorax or hemothorax. Accidental dislocation of the catheter occurred in four patients (9%) over 3-10 days after the first procedure.
CONCLUSIONS: In our experience, real-time US-guided pleural-space puncture, performed at bedside, with the patient in the supine position, followed by placement of a pigtail catheter for drainage of effusion, is safe to use and has a high rate of technical success in pediatric patients.
© 2015 Wiley Periodicals, Inc. J Clin Ultrasound 44:284-289, 2016. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  chest; children; interventional radiology; pigtail catheter; ultrasonography

Mesh:

Year:  2015        PMID: 26332031     DOI: 10.1002/jcu.22294

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  3 in total

1.  Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion.

Authors:  Weitian Cao; Yi Wang; Ningming Zhou; Bing Xu
Journal:  Oncol Lett       Date:  2016-10-12       Impact factor: 2.967

Review 2.  Point-of-Care Thoracic Ultrasonography in Patients With Cirrhosis and Liver Failure.

Authors:  Kamal Kajal; Madhumita Premkumar; Sreedhara B Chaluvashetty; Harish Bhujade; Anand V Kulkarni
Journal:  Cureus       Date:  2021-06-10

3.  Morbidity and mortality of iatrogenic hemothorax occurring in a cohort of liver transplantation recipients: a multicenter observational study.

Authors:  Fabrizio Panaro; Bader Al Taweel; Piera Leon; Davide Ghinolfi; Giuliano Testa; Marit Kalisvaart; Paolo Muiesan; Renato Romagnoli; Mickael Lesurtel; Gianluca Cassese; Stephanie Truant; Pietro Addeo; Mauricio Sainz-Barrica; Umberto Baccarani; Paolo De Simone; Fouad Belafia; Astrid Herrero; Francis Navarro
Journal:  Updates Surg       Date:  2021-07-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.