Literature DB >> 26329926

Hand-held portable desorption atmospheric pressure chemical ionization ion source for in situ analysis of nitroaromatic explosives.

Fred P M Jjunju1,2, Simon Maher1, Anyin Li3, Sarfaraz U Syed4, Barry Smith1,2, Ron M A Heeren4, Stephen Taylor1,2, R Graham Cooks3.   

Abstract

A novel, lightweight (0.6 kg), solvent- and gas-cylinder-free, hand-held ion source based on desorption atmospheric pressure chemical ionization has been developed and deployed for the analysis of nitroaromatic explosives on surfaces in open air, offering portability for in-field analysis. A small, inexpensive, rechargeable lithium polymer battery was used to power the custom-designed circuitry within the device, which generates up to ±5 kV dc voltage to ignite a corona discharge plasma in air for up to 12 h of continuous operation, and allowing positive- and negative-ion mass spectrometry. The generated plasma is pneumatically transported to the surface to be interrogated by ambient air at a rate of 1-3.5 L/min, compressed using a small on-board diaphragm pump. The plasma source allows liquid or solid samples to be examined almost instantaneously without any sample preparation in the open environment. The advantages of low carrier gas and low power consumption (<6 W), as well as zero solvent usage, have aided in developing the field-ready, hand-held device for trigger-based, "near-real-time" sampling/ionization. Individual nitroaromatic explosives (such as 2,4,6-trinitrotoluene) can be easily detected in amounts as low as 5.8 pg with a linear dynamic range of at least 10 (10-100 pg), a relative standard deviation of ca. 7%, and an R(2) value of 0.9986. Direct detection of several nitroaromatic compounds in a complex mixture without prior sample preparation is demonstrated, and their identities are confirmed by tandem mass spectrometry fragmentation patterns.

Entities:  

Year:  2015        PMID: 26329926     DOI: 10.1021/acs.analchem.5b02684

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

Review 2.  Recent advances in ambient mass spectrometry of trace explosives.

Authors:  Thomas P Forbes; Edward Sisco
Journal:  Analyst       Date:  2018-04-30       Impact factor: 4.616

3.  Direct Analysis and Quantification of Metaldehyde in Water using Reactive Paper Spray Mass Spectrometry.

Authors:  Simon Maher; Fred P M Jjunju; Deidre E Damon; Hannah Gorton; Yosef S Maher; Safaraz U Syed; Ron M A Heeren; Iain S Young; Stephen Taylor; Abraham K Badu-Tawiah
Journal:  Sci Rep       Date:  2016-10-21       Impact factor: 4.379

4.  Effects of the source gap on transmission efficiency of a quadrupole mass spectrometer.

Authors:  Mariya J Antony Joseph; David G McIntosh; J Raymond Gibson; Stephen Taylor
Journal:  Rapid Commun Mass Spectrom       Date:  2018-05-15       Impact factor: 2.419

5.  Analysis of non-conjugated steroids in water using paper spray mass spectrometry.

Authors:  Fred P M Jjunju; Deidre E Damon; David Romero-Perez; Iain S Young; Ryan J Ward; Alan Marshall; Simon Maher; Abraham K Badu-Tawiah
Journal:  Sci Rep       Date:  2020-07-01       Impact factor: 4.379

6.  Rapid Scotch Whisky Analysis and Authentication using Desorption Atmospheric Pressure Chemical Ionisation Mass Spectrometry.

Authors:  Barry L Smith; David M Hughes; Abraham K Badu-Tawiah; Rebecca Eccles; Ian Goodall; Simon Maher
Journal:  Sci Rep       Date:  2019-05-29       Impact factor: 4.379

7.  In-Situ Analysis of Essential Fragrant Oils Using a Portable Mass Spectrometer.

Authors:  Fred P M Jjunju; Stamatios Giannoukos; Alan Marshall; Stephen Taylor
Journal:  Int J Anal Chem       Date:  2019-04-01       Impact factor: 1.885

8.  Rapid geographical indication of peppercorn seeds using corona discharge mass spectrometry.

Authors:  Preeyarad Charoensumran; Monrawat Rauytanapanit; Nontawat Sricharoen; Barry L Smith; Kanet Wongravee; Simon Maher; Thanit Praneenararat
Journal:  Sci Rep       Date:  2021-08-09       Impact factor: 4.379