Literature DB >> 26329696

The Diagnostic Value of Micropure Imaging in Breast Suspicious Microcalcificaion.

Rong Tan1, Ying Xiao2, Qi Tang1, Ying Zhang1, Hui Chen3, Xiancheng Fan4.   

Abstract

RATIONALE AND
OBJECTIVES: The purpose of this study was to evaluate the diagnostic value of Micropure Imaging (MI) in breast lesions differentiation by comparison with B-mode ultrasonography (B-US) and Doppler ultrasonography (DU).
MATERIALS AND METHODS: A total of 135 consecutive patients (all females) with 135 suspicious lesions were examined and skin marked by MI before mammotome biopsies. All patients (age range, 20-86 years; mean age, 42.5 ± 15.6 years) were the first onset, not in the pregnancy or lactation and had no history of radiation or chemotherapy. The maximum diameter of lesions ranged from 0.2 to 9.6 cm (average 1.98 ± 1.3 cm). Their final diagnoses were obtained by histologic examination. The study protocol was approved by the hospital review board; each patient gave written informed consent.
RESULTS: One hundred thirty-five breast lesions were classified into 90 nonmalignant and 45 malignant types. To 86 breast lesions with microcalcification, MI showed more microcalcification and coincided better with pathology results than B-US did (P < .05). The specificity of MI was higher than that of B-US and DU; the sensitivity of DU was significantly higher than that of B-US and MI (P < .001). By combining B-US, DU, and MI, the detection accuracy was 86.7%. Receiver-operator characteristic curves showed the area under the curve of B-US, DU, and MI was 0.865, 0.934, and 0.923(P = .000), respectively. Moreover, the interobserver agreements of MI were the highest, 0.922 (observer 1 vs. observer 2), 0.866 (observer 1 vs. observer 3), and 0.916 (observer 2 vs. observer 3).
CONCLUSIONS: MI as an adjunct ultrasound modality holds some promise in locating and differentiating breast lesions.
Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  B-US; DU; MI; microcalcification

Mesh:

Year:  2015        PMID: 26329696     DOI: 10.1016/j.acra.2015.07.012

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  3 in total

1.  Ultrasound-guided biopsy of breast calcifications using a new image processing technique: initial experience.

Authors:  Almir Galvão Vieira Bitencourt; Luciana Graziano; Camila Souza Guatelli; Maria Luiza Lima Albuquerque; Elvira Ferreira Marques
Journal:  Radiol Bras       Date:  2018 Mar-Apr

2.  Clinical Utility of MicroPure US Imaging for Breast Microcalcifications.

Authors:  Heerin Lee; Sung Hun Kim; Bong Joo Kang; Jeong Min Lee
Journal:  J Korean Soc Radiol       Date:  2021-12-11

3.  The Utility of MicroPure™ Ultrasound Technique in Assessing Grouped Microcalcifications without a Mass on Mammography.

Authors:  Ah Young Park; Bo Kyoung Seo; Kyu Ran Cho; Ok Hee Woo
Journal:  J Breast Cancer       Date:  2016-03-25       Impact factor: 3.588

  3 in total