Literature DB >> 26329655

A lab-on-a-chip system integrating tissue sample preparation and multiplex RT-qPCR for gene expression analysis in point-of-care hepatotoxicity assessment.

Geok Soon Lim1, Joseph S Chang, Zhang Lei, Ruige Wu, Zhiping Wang, Kemi Cui, Stephen Wong.   

Abstract

A truly practical lab-on-a-chip (LOC) system for point-of-care testing (POCT) hepatotoxicity assessment necessitates the embodiment of full-automation, ease-of-use and "sample-in-answer-out" diagnostic capabilities. To date, the reported microfluidic devices for POCT hepatotoxicity assessment remain rudimentary as they largely embody only semi-quantitative or single sample/gene detection capabilities. In this paper, we describe, for the first time, an integrated LOC system that is somewhat close to a practical POCT hepatotoxicity assessment device - it embodies both tissue sample preparation and multiplex real-time RT-PCR. It features semi-automation, is relatively easy to use, and has "sample-in-answer-out" capabilities for multiplex gene expression analysis. Our tissue sample preparation module incorporating both a microhomogenizer and surface-treated paramagnetic microbeads yielded high purity mRNA extracts, considerably better than manual means of extraction. A primer preloading surface treatment procedure and the single-loading inlet on our multiplex real-time RT-PCR module simplify off-chip handling procedures for ease-of-use. To demonstrate the efficacy of our LOC system for POCT hepatotoxicity assessment, we perform a preclinical animal study with the administration of cyclophosphamide, followed by gene expression analysis of two critical protein biomarkers for liver function tests, aspartate transaminase (AST) and alanine transaminase (ALT). Our experimental results depict normalized fold changes of 1.62 and 1.31 for AST and ALT, respectively, illustrating up-regulations in their expression levels and hence validating their selection as critical genes of interest. In short, we illustrate the feasibility of multiplex gene expression analysis in an integrated LOC system as a viable POCT means for hepatotoxicity assessment.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26329655     DOI: 10.1039/c5lc00798d

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  3 in total

Review 1.  Point-of-Care Diagnostics: Recent Developments in a Connected Age.

Authors:  Samiksha Nayak; Nicole R Blumenfeld; Tassaneewan Laksanasopin; Samuel K Sia
Journal:  Anal Chem       Date:  2016-12-13       Impact factor: 6.986

2.  From Lab on a Chip to Point of Care Devices: The Role of Open Source Microcontrollers.

Authors:  Trieu Nguyen; Sune Zoëga Andreasen; Anders Wolff; Dang Duong Bang
Journal:  Micromachines (Basel)       Date:  2018-08-14       Impact factor: 2.891

3.  A Complete Protocol for Rapid and Low-Cost Fabrication of Polymer Microfluidic Chips Containing Three-Dimensional Microstructures Used in Point-of-Care Devices.

Authors:  Trieu Nguyen; Aaydha Chidambara Vinayaka; Dang Duong Bang; Anders Wolff
Journal:  Micromachines (Basel)       Date:  2019-09-19       Impact factor: 2.891