Influence of Head Orientation in Linear Measurement for Implant Planning in Cone Beam Computed Tomography.

Abbas Shokri1, Samira Khajeh1, Atefeh Khavid2, Sara Tabari1, Shiva Yarmohammadi1.   

Abstract

AIM: Use of dental implants in edentulous patients has become a common treatment modality. Treatment of such implants requires radiographic evaluation, and in most cases several different imaging techniques are necessary in order to evaluate the height, width and the structure of bone at implant site. The aim of this study was to evaluate the influence of head orientation in linear measurement for implant planning in cone beam computed tomography (CBCT).
MATERIALS AND METHODS: In the present in vitro study, 11 human dry mandibles were used. The width and height of bone at the central, canine and molar teeth areas were measured on the left and right sides by using digital calipers (as gold standard) and on CBCT images with Reaxis option and no Reaxis. Data were analyzed with Statistical package for the social sciences (SPSS) 18, using pair t-test, Tukey test and intraclass correlation (ICC).
RESULTS: Data were collected by evaluation of 11 skulls and 66 samples on the whole. There were no significant differences in bone width in any area in both Reaxis and no Reaxis option (p > 0.05). There were significant differences in bone height in the central (p = 0.005) and molar teeth areas (p = 0.010). The results did not show any significant differences between the observers (p = 0.329).
CONCLUSION: Using the Reaxis option does not affect the measurement of bone width, while use of this option can make a significant difference for height measurements.

Entities:  

Keywords:  Bone width; Bone height; CBCT; Head orientation; Reaxis option; Reslice option

Mesh:

Substances:

Year:  2015        PMID: 26329408     DOI: 10.5005/jp-journals-10024-1719

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  2 in total

1.  United Reference Method for three-dimensional treatment evaluation.

Authors:  Shereef Shahen; Manuel O Lagravère; Gennaro Carrino; Fady Fahim; Reham Abdelsalam; Carlos Flores-Mir; Letizia Perillo
Journal:  Prog Orthod       Date:  2018-12-03       Impact factor: 2.750

2.  Mesiodistal Measurements for Dental Implant Planning: A Prospective Clinical Study of Linear Measurements on Cone-Beam Computed Tomography Images in Comparison with Caliper-Based Measurements on Plaster Casts.

Authors:  Lydia Vazquez; Ramona Buser; Jean-Pierre Carrel
Journal:  Dent J (Basel)       Date:  2022-09-07
  2 in total