Change in posture during sleep causes errors in non-invasive automatic blood pressure recordings.

A Schwan1, K Pavek.   

Abstract

When measured with automatic non-invasive monitors blood pressure is seen to fluctuate during sleep. The recorded blood pressure is influenced by the vertical distance between the heart level (zero reference) and the level of the brachial artery at the point of compression by the inflated cuff. In 20 randomly selected men, blood pressure was measured every 20 min during the night. The difference between consecutive recordings was 7.6 mmHg +/- 5.7/5.0 (s.d.), range 0-23/0-20 mmHg. The maximum blood pressure difference was 19 +/- 6.8/15 +/- 6.0, range 7-32/6-26 mmHg. These results were compared with the difference in blood pressure recorded on the left arm in 20 volunteers changing posture between four standardized recumbent postures. The posture change caused an average blood pressure difference of 9 +/- 6.1/9 +/- 6.5 mmHg, range 0-28/0-30 mmHg. The maximum blood pressure difference was 15 +/- 5.1/12 +/- 5.5 mmHg, range 5-27/(-)2-23 mmHg recorded between lying supine and lying on the right side. The similarity between differences and the variation in blood pressure during the recumbent posture indicates that changes in posture cause most of the night-time blood pressure variation recorded with non-invasive devices.

Entities:  

Mesh:

Year:  1989        PMID: 2632746     DOI: 10.1097/00004872-198900076-00027

Source DB:  PubMed          Journal:  J Hypertens Suppl        ISSN: 0952-1178


  4 in total

1.  Daily environmental differences in blood pressure and heart rate variability in healthy premenopausal women.

Authors:  Gary D James; Dana H Bovbjerg; Leah A Hill
Journal:  Am J Hum Biol       Date:  2014-08-25       Impact factor: 1.937

2.  Toward Automation of the Supine Pressor Test for Preeclampsia.

Authors:  Hamna J Qureshi; Jessica L Ma; Jennifer L Anderson; Brett M Bosinski; Aditi Acharya; Rachel D Bennett; David M Haas; Abigail D Cox; George R Wodicka; David G Reuter; Craig J Goergen
Journal:  J Eng Sci Med Diagn Ther       Date:  2019-11-19

3.  The cuffless SOMNOtouch NIBP device shows poor agreement with a validated oscillometric device during 24-h ambulatory blood pressure monitoring.

Authors:  Jakob Nyvad; Kent L Christensen; Niels Henrik Buus; Mark Reinhard
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-12-17       Impact factor: 3.738

4.  What is the true blood pressure? Smirk revisited.

Authors:  Thomas G Pickering
Journal:  J Clin Hypertens (Greenwich)       Date:  2005-07       Impact factor: 3.738

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.