Literature DB >> 2632744

Comparison of Finapres non-invasive beat-to-beat finger blood pressure with intrabrachial artery pressure during and after bicycle ergometry.

R N Idema1, A H van den Meiracker, B P Imholz, A J Man in 't Veld, J J Settels, H J Ritsema van Eck, M A Schalekamp.   

Abstract

To evaluate the accuracy of continuous non-invasive blood pressure measurements in the finger during exercise, Finapres blood pressures of six normotensive healthy males were measured during increasing levels of bicycle exercise, using simultaneously registered ipsilateral intrabrachial artery pressures as a reference. At rest, finger systolic blood pressure was higher and finger diastolic and mean arterial pressures were lower than the corresponding intrabrachial pressures in five of the six subjects. During exercise, average finger diastolic and mean arterial pressures did not differ further from these intrabrachial pressures, but finger systolic pressure increased considerably more than the direct systolic pressure, exceeding it by 26 +/- 20 mmHg (mean +/- s.d.) at maximal exercise. This latter finding potentially limits the use of finger blood pressure measurements during exercise.

Mesh:

Year:  1989        PMID: 2632744     DOI: 10.1097/00004872-198900076-00025

Source DB:  PubMed          Journal:  J Hypertens Suppl        ISSN: 0952-1178


  10 in total

1.  Increases in central blood volume modulate carotid baroreflex resetting during dynamic exercise in humans.

Authors:  Shigehiko Ogoh; James P Fisher; Paul J Fadel; Peter B Raven
Journal:  J Physiol       Date:  2007-02-22       Impact factor: 5.182

2.  Continuous finger arterial pressure: utility in the cardiovascular laboratory.

Authors:  B P Imholz; W Wieling; G J Langewouters; G A van Montfrans
Journal:  Clin Auton Res       Date:  1991-03       Impact factor: 4.435

3.  Effects of endurance training on the maximal voluntary activation level of the knee extensor muscles.

Authors:  F Zghal; V Martin; A Thorkani; P J Arnal; Z Tabka; F Cottin
Journal:  Eur J Appl Physiol       Date:  2013-12-25       Impact factor: 3.078

4.  Compressed storage of arterial pressure waveforms by selection of significant points.

Authors:  P M de Graaf; J van Goudoever; K H Wesseling
Journal:  Med Biol Eng Comput       Date:  1997-09       Impact factor: 2.602

5.  Catheter-manometer system damped blood pressures detected by neural nets.

Authors:  A Prentza; K H Wesseling
Journal:  Med Biol Eng Comput       Date:  1995-07       Impact factor: 2.602

6.  Autonomic nervous control of heart rate during blood-flow restricted exercise in man.

Authors:  J C Sun; O Eiken; I B Mekjavic
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993

7.  Evaluation of non-invasive blood pressure measurement by the Finapres method at rest and during dynamic exercise in subjects with cardiovascular insufficiency.

Authors:  B Silke; J P Spiers; S Boyd; E Graham; G McParland; M E Scott
Journal:  Clin Auton Res       Date:  1994-04       Impact factor: 4.435

8.  Angiotensin II receptor blockade with single doses of valsartan in healthy, normotensive subjects.

Authors:  P Müller; T Cohen; M de Gasparo; A Sioufi; A Racine-Poon; H Howald
Journal:  Eur J Clin Pharmacol       Date:  1994       Impact factor: 2.953

9.  Effect of oral glucocorticoid intake on autonomic cardiovascular control.

Authors:  F Cottin; V Malcurat; H Zorgati; F Prieur; Z Labsy; M C Do; O Gagey; K Collomp
Journal:  Springerplus       Date:  2015-10-19

10.  Effect of spinal manipulative treatment on cardiovascular autonomic control in patients with acute low back pain.

Authors:  Mohamed Younes; Karine Nowakowski; Benoit Didier-Laurent; Michel Gombert; François Cottin
Journal:  Chiropr Man Therap       Date:  2017-12-04
  10 in total