Literature DB >> 26324387

Feasibility and safety of a fully covered self-expandable metal stent with antimigration properties for EUS-guided pancreatic duct drainage: early and midterm outcomes (with video).

Dongwook Oh1, Do Hyun Park1, Min Keun Cho1, Kwangwoo Nam1, Tae Jun Song1, Sang Soo Lee1, Dong-Wan Seo1, Sung Koo Lee1, Myung-Hwan Kim1.   

Abstract

BACKGROUND AND AIMS: Recently, EUS-guided pancreatic duct drainage (EUS-PD) has been used for patients in whom endoscopic retrograde pancreatography (ERP) has failed. Stent-related adverse events such as stent migrations, failures in stent placement, or pancreatic fluid leakages have been of concern in transmural plastic stenting procedures. The aim of this study is to evaluate the feasibility and safety of EUS-PD with a fully covered self-expandable metal stent (FCSEMS) for patients with obstructive pancreatitis who failed ERP.
METHODS: Twenty-five consecutive patients with painful obstructive pancreatitis underwent EUS-PD with a FCSEMS after failed ERP. Technical and clinical success, adverse events, and stent patency were assessed.
RESULTS: EUS-PD was successful in all 25 patients (technical success rate, 100%), and symptoms improved in all patients (clinical success rate, 100%). EUS-guided pancreaticogastrostomy (n = 23), pancreaticoduodenostomy (n = 1), and pancreaticojejunostomy (n = 1) were performed. Pain scores improved significantly after FCSEMS placement (P = .001). Early mild grade adverse events occurred in 5 patients (20%), 4 with self-limited abdominal pain and 1 with minor bleeding. No other adverse events related to FCSEMS, including stent migration, stent clogging, pancreatic sepsis, and stent-induced ductal stricture, were observed during follow-up periods. Mean stent patency duration was 126.9 days during mean follow-up periods (221.1 days).
CONCLUSIONS: EUS-PD with an FCSEMS may be technically feasible and relatively safe for patients who fail conventional ERP. Further randomized trials comparing EUS-PD with long-term FCSEMS and plastic stents for patients with painful obstructive pancreatitis after failed ERCP should be encouraged.
Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26324387     DOI: 10.1016/j.gie.2015.07.015

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  23 in total

Review 1.  When ERCP Fails: EUS-Guided Access to Biliary and Pancreatic Ducts.

Authors:  Abdelhai Abdelqader; Michel Kahaleh
Journal:  Dig Dis Sci       Date:  2022-04-04       Impact factor: 3.199

Review 2.  Therapeutic endoscopic ultrasound.

Authors:  Rodrigo Duarte-Chavez; Michel Kahaleh
Journal:  Transl Gastroenterol Hepatol       Date:  2022-04-25

3.  Efficacy of Biodegradable Polydioxanone and Polylactic Acid Braided Biodegradable Biliary Stents for the Management of Benign Biliary Strictures.

Authors:  Weixing Zhang; Fariha Kanwal; Muhammad Fayyaz Ur Rehman; Xinjian Wan
Journal:  Turk J Gastroenterol       Date:  2021-08       Impact factor: 1.555

4.  Turkish Gastroenterology Association, Pancreas Study Group, Chronic Pancreatitis Committee Consensus Report.

Authors:  Müjde Soytürk; Göksel Bengi; Dilek Oğuz; İsmail Hakkı Kalkan; Mehmet Yalnız; Mustafa Tahtacı; Kadir Demir; Elmas Kasap; Nevin Oruç; Nalan Gülşen Ünal; Orhan Sezgin; Osman Özdoğan; Engin Altıntaş; Serkan Yaraş; Erkan Parlak; Aydın Şeref Köksal; Murat Saruç; Hakan Ünal; Belkıs Ünsal; Süleyman Günay; Deniz Duman; Alper Yurçi; Sabite Kacar; Levent Filik
Journal:  Turk J Gastroenterol       Date:  2020-11       Impact factor: 1.555

Review 5.  Endoscopic Ultrasound (EUS)-Guided Pancreatic Duct Drainage: The Basics of When and How to Perform EUS-Guided Pancreatic Duct Interventions.

Authors:  Christopher G Chapman; Irving Waxman; Uzma D Siddiqui
Journal:  Clin Endosc       Date:  2016-03-25

6.  Fabrication of a silver particle-integrated silicone polymer-covered metal stent against sludge and biofilm formation and stent-induced tissue inflammation.

Authors:  Tae Hoon Lee; Bong Seok Jang; Min Kyo Jung; Chan Gi Pack; Jun-Ho Choi; Do Hyun Park
Journal:  Sci Rep       Date:  2016-10-14       Impact factor: 4.379

Review 7.  Endoscopic Ultrasound-Guided Pancreatobiliary Endoscopy in Surgically Altered Anatomy.

Authors:  Pichamol Jirapinyo; Linda S Lee
Journal:  Clin Endosc       Date:  2016-11-29

8.  Endoscopic ultrasound-guided pancreaticogastrostomy for symptomatic pancreatic duct obstruction caused by migrated pancreatic stent.

Authors:  Lei Lu; Hang-Bin Jin; Jian-Feng Yang; Xiao-Feng Zhang
Journal:  World J Gastrointest Endosc       Date:  2017-10-16

9.  Safety and efficacy of EUS-guided pancreatic duct drainage in symptomatic main pancreatic duct obstruction: Is there still a place for surgery?

Authors:  Arthur Falque; Mohamed Gasmi; Marc Barthet; Jean-Michel Gonzalez
Journal:  Endosc Int Open       Date:  2021-05-27

Review 10.  Past, Present, and Future of Gastrointestinal Stents: New Endoscopic Ultrasonography-Guided Metal Stents and Future Developments.

Authors:  Hee Seung Lee; Moon Jae Chung
Journal:  Clin Endosc       Date:  2016-03-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.