Literature DB >> 26320633

Disposable integrated bismuth citrate-modified screen-printed immunosensor for ultrasensitive quantum dot-based electrochemical assay of C-reactive protein in human serum.

Christos Kokkinos1, Mamas Prodromidis2, Anastasios Economou3, Panagiota Petrou4, Sotirios Kakabakos4.   

Abstract

A novel immunosensor based on graphite screen-printed electrodes (SPEs) modified with bismuth citrate was developed for the voltammetric determination of C-reactive protein (CRP) in human serum using quantum dots (QDs) labels. The sandwich-type immunoassay involved physisorption of CRP capture antibody on the surface of the sensor, sequential immunoreactions with CRP and biotinylated CRP reporter antibody and finally reaction with streptavidin-conjugated PbS QDs. The quantification of the target protein was performed with acidic dissolution of the PbS QDs and anodic stripping voltammetric detection of the Pb(II) released. Detection was performed at bismuth nanodomains formed on the sensor surface during the electrolytic preconcentration step, as bismuth citrate was reduced to metallic bismuth simultaneously with the deposition of Pb on the surface of the immunosensor. Under optimal conditions, the response was linear over the range 0.2-100 ng mL(-1) CRP and the limit of detection was 0.05 ng mL(-1) CRP. Since the modified SPE serves as both the biorecognition element and the QDs reader, the analytical procedure is simplified, the drawbacks of existing electroplated immunosensors are minimized while the proposed disposable sensing platform provides convenient, low-cost and ultrasensitive detection of proteins and wider scope for mass-production.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  C-reactive protein; Immunosensor; Quantum dots; Screen-printed electrode; Stripping voltammetry

Mesh:

Substances:

Year:  2015        PMID: 26320633     DOI: 10.1016/j.aca.2015.05.035

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

1.  An origami paper-based electrochemical immunoassay for the C-reactive protein using a screen-printed carbon electrode modified with graphene and gold nanoparticles.

Authors:  Suchanat Boonkaew; Sudkate Chaiyo; Sakda Jampasa; Sirirat Rengpipat; Weena Siangproh; Orawon Chailapakul
Journal:  Mikrochim Acta       Date:  2019-02-02       Impact factor: 5.833

Review 2.  Sensors and Biosensors for C-Reactive Protein, Temperature and pH, and Their Applications for Monitoring Wound Healing: A Review.

Authors:  Pietro Salvo; Valentina Dini; Arno Kirchhain; Agata Janowska; Teresa Oranges; Andrea Chiricozzi; Tommaso Lomonaco; Fabio Di Francesco; Marco Romanelli
Journal:  Sensors (Basel)       Date:  2017-12-19       Impact factor: 3.576

3.  Nanobiosensors in diagnostics.

Authors:  Alejandro Chamorro-Garcia; Arben Merkoçi
Journal:  Nanobiomedicine (Rij)       Date:  2016-11-24

Review 4.  Screen-Printed Electrodes (SPE) for In Vitro Diagnostic Purpose.

Authors:  Nicolae-Bogdan Mincu; Veronica Lazar; Dana Stan; Carmen Marinela Mihailescu; Rodica Iosub; Andreea Lorena Mateescu
Journal:  Diagnostics (Basel)       Date:  2020-07-26

Review 5.  Electrochemical (Bio)Sensors for Pesticides Detection Using Screen-Printed Electrodes.

Authors:  Beatriz Pérez-Fernández; Agustín Costa-García; Alfredo de la Escosura- Muñiz
Journal:  Biosensors (Basel)       Date:  2020-04-02

6.  Voltammetric Immunosensor to Track a Major Peanut Allergen (Ara h 1) in Food Products Employing Quantum Dot Labels.

Authors:  Maria Freitas; Henri P A Nouws; Cristina Delerue-Matos
Journal:  Biosensors (Basel)       Date:  2021-10-29

Review 7.  Recent Advances in the Fabrication and Application of Screen-Printed Electrochemical (Bio)Sensors Based on Carbon Materials for Biomedical, Agri-Food and Environmental Analyses.

Authors:  Gareth Hughes; Kelly Westmacott; Kevin C Honeychurch; Adrian Crew; Roy M Pemberton; John P Hart
Journal:  Biosensors (Basel)       Date:  2016-09-28

Review 8.  Desktop Fabrication of Lab-On-Chip Devices on Flexible Substrates: A Brief Review.

Authors:  Ahmad Zaman Qamar; Mohtashim Hassan Shamsi
Journal:  Micromachines (Basel)       Date:  2020-01-23       Impact factor: 2.891

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.