Literature DB >> 26318407

Level 2 validation of a flow cytometric method for detection of Escherichia coli O157:H7 in raw spinach.

Anna J Williams1, Willie M Cooper2, Christine V Summage-West3, Lillie M Sims4, Robert Woodruff5, Jessica Christman6, Ted J Moskal7, Shawn Ramsaroop8, John B Sutherland9, Pierre Alusta10, Jon G Wilkes11, Dan A Buzatu12.   

Abstract

The Bacteriological Analytical Manual (BAM) method currently used by the United States Food and Drug Administration (FDA) to detect Escherichia coli O157:H7 in spinach was systematically compared to a new flow cytometry based method. This Food and Drug Administration (FDA) level 2 external laboratory validation study was designed to determine the latter method's sensitivity and speed for analysis of this pathogen in raw spinach. Detection of target cell inoculations with a low cell count is critical, since enterohemorrhagic strains of E. coli require an infective dose of as few as 10 cells (Schmid-Hempel and Frank, 2007). Although, according to the FDA, the infectious dose is unknown (Food and Drug Administration, 1993). Therefore, the inoculation level into the spinach, a total of 2.0±2.6 viable E. coli O157 cells, was specified to yield between 25% and 75% detection by the new method, out of 20 samples (10 positives and 10 negatives). This criterion was met in that the new method detected 60% of the nominally positive samples; the corresponding sensitivity of the reference method was 50%. For both methods the most likely explanation for false negatives was that no viable cells were actually introduced into the sample. In this validation study, the flow cytometry method was equal to the BAM in sensitivity and far superior in speed. Published by Elsevier B.V.

Entities:  

Keywords:  Escherichia coli O157; Flow cytometry; Food pathogens; Microorganisms; Public health

Mesh:

Year:  2015        PMID: 26318407     DOI: 10.1016/j.ijfoodmicro.2015.08.011

Source DB:  PubMed          Journal:  Int J Food Microbiol        ISSN: 0168-1605            Impact factor:   5.277


  2 in total

1.  Specific Detection and Enumeration of Burkholderia cepacia Complex by Flow Cytometry Using a Fluorescence-Labeled Oligonucleotide Probe.

Authors:  Soumana Daddy Gaoh; Anna Williams; David Le; Ohgew Kweon; Pierre Alusta; Dan A Buzatu; Youngbeom Ahn
Journal:  Microorganisms       Date:  2022-06-07

2.  Rapid Flow Cytometry Detection of a Single Viable Escherichia coli O157:H7 Cell in Raw Spinach Using a Simplified Sample Preparation Technique.

Authors:  Anna J Williams; Willie M Cooper; Shawn Ramsaroop; Pierre Alusta; Dan A Buzatu; Jon G Wilkes
Journal:  Front Microbiol       Date:  2017-08-14       Impact factor: 5.640