Literature DB >> 26317321

Development and validation of a rapid LC-MS/MS method to quantify letrozole in human plasma and its application to therapeutic drug monitoring.

Rong Shao1, Ling-yan Yu1, Hong-gang Lou1, Zou-rong Ruan1, Bo Jiang1, Jin-liang Chen1.   

Abstract

A selective, rapid, and sensitive liquid chromatography-tandem mass spectrometry(LC-MS/MS) method was developed and validated for the determination of letrozole (LTZ) in human plasma, using anastrozole as internal standard (IS). Sample preparation was performed by one-step protein precipitation with methanol. The analyte and IS were chromatographed on a reversed-phase YMC-ODS-C18 column (2.0 × 100 mm i.d., 3 µm) with a flow rate of 0.3 mL/min. The mobile phase consisted of water containing 0.1% formic acid (v/v) and methanol containing 0.1% formic acid (v/v). The mass spectrometer was operated in selected reaction monitoring mode through electrospray ionization ion mode using the transitions of m/z 286.2 → 217.1 for LTZ and m/z 294.1 → 225.1 for IS, respectively. The method was validated for selectivity, linearity, lower limit of quantitation, precision, accuracy, matrix effects and stability in accordance with the US Food and Drug Administration guidelines. Linear calibration curves were 1.0-60.0 ng/mL. Intra- and inter-batch precision (CV) for LTZ were <9.34%, and the accuracy ranged from 97.43 to 105.17%. This method was successfully used for the analysis of samples from patients treated with LTZ in the dose of 2.5 mg/day. It might be suitable for therapeutic drug monitoring of these patients and contribute to predict the risk of adverse reactions.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  LC-MS/MS; human plasma; letrozole; therapeutic drug monitoring

Mesh:

Substances:

Year:  2015        PMID: 26317321     DOI: 10.1002/bmc.3607

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  4 in total

1.  Development and Validation of a Novel LC-MS/MS Method for the Simultaneous Determination of Abemaciclib, Palbociclib, Ribociclib, Anastrozole, Letrozole, and Fulvestrant in Plasma Samples: A Prerequisite for Personalized Breast Cancer Treatment.

Authors:  Lu Turković; Luka Bočkor; Oscar Ekpenyong; Tajana Silovski; Mila Lovrić; Slaven Crnković; Biljana Nigović; Miranda Sertić
Journal:  Pharmaceuticals (Basel)       Date:  2022-05-16

2.  SPE-UPLC-MS/MS assay for determination of letrozole in human plasma and its application to bioequivalence study in healthy postmenopausal Indian women.

Authors:  Pravin G Vanol; Puran Singhal; Priyanka A Shah; Jaivik V Shah; Pranav S Shrivastav; Mallika Sanyal
Journal:  J Pharm Anal       Date:  2016-05-20

3.  Simultaneous quantification of palbociclib, ribociclib and letrozole in human plasma by a new LC-MS/MS method for clinical application.

Authors:  Bianca Posocco; Mauro Buzzo; Ariana Soledad Poetto; Marco Orleni; Sara Gagno; Martina Zanchetta; Valentina Iacuzzi; Michela Guardascione; Fabio Puglisi; Debora Basile; Giacomo Pelizzari; Elena Marangon; Giuseppe Toffoli
Journal:  PLoS One       Date:  2020-02-07       Impact factor: 3.240

4.  Simultaneous Quantification of Aromatase Inhibitors and Estrogens in Postmenopausal Breast Cancer Patients.

Authors:  Bjørn-Erik Bertelsen; Kristin Viste; Thomas Helland; Magnus Hagland; Håvard Søiland; Jürgen Geisler; Tone Hoel Lende; Per Eystein Lønning; Jørn V Sagen; Gunnar Mellgren; Bjørg Almås
Journal:  J Clin Endocrinol Metab       Date:  2022-04-19       Impact factor: 6.134

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.