Literature DB >> 26314883

Transcatheter aortic valve implantation in patients with bicuspid aortic valve: a series of cases.

Mikołaj Kosek1, Adam Witkowski, Maciej Dąbrowski, Jan Jastrzębski, Ilona Michałowska, Zbigniew Chmielak, Marcin Demkow, Ewa Księżycka-Majczyńska, Piotr Michałek, Piotr Szymański, Tomasz Hryniewiecki, Janina Stępińska, Ewa Sitkowska-Rysiak, Witold Rużyłło.   

Abstract

BACKGROUND: Bicuspid aortic valve (BAV) has been considered a relative contraindication for transcatheter aortic valve implantation (TAVI). Due to more oval shape of the BAV annulus compared to tricuspid aortic valve, the procedure has been discouraged because of an increased risk of stent assembly displacement, uneven expansion, post-procedure paravalvular leakage, stent valve distortion, or other malfunction after implantation. For the same reasons patients with BAV have been excluded from the majority of clinical TAVI trials. AIM: To evaluate the efficacy and safety of TAVI in patients with BAV stenosis.
METHODS: We analysed a group of 104 patients admitted to our institution for TAVI between January 2009 and May 2012. During pre-procedure evaluation, transthoracic and transoesophageal (TEE) echocardiography as well as angio-computed tomography (CT) scan were performed to assess aortic valve anatomy and morphology. Appropriate measurements and detailed analyses of imaging data have been accomplished to select optimal access site, prosthesis size as well as to plan the procedure. BAVs were recorded in seven patients (6.7%; mean age 77.7 years). These patients presented with severe symptomatic aortic valve stenosis with a mean aortic valve area of 0.55 cm² (0.46-0.7 cm²) as measured in TEE. All of the patients had been disqualified from surgical valve replacement due to high surgical risk with a mean logistic Euroscore of 19.9%. All of them successfully underwent TAVI using CoreValve (n = 5) or Sapien (n = 2) valves. Follow-up was completed at 30 days, and six and 12 months after the procedure.
RESULTS: During follow-up one patient developed an elliptic distortion of the aortic prosthesis in CT, although it did not result in significant malfunctioning of the implant. One patient died of infective endocarditis 30 days after the procedure. Survivors at 30-day follow-up had mild to moderate aortic insufficiency, and it did not deteriorate after six months. At one year follow-up six out of seven patients remained alive. They achieved significant functional improvement by New York Heart Association class compared to baseline.
CONCLUSIONS: TAVI may constitute an alternative treatment option for high-risk patients with BAV, resulting in a low periprocedural mortality rate, and good 30-day, six-month, and one-year outcomes.

Entities:  

Mesh:

Year:  2015        PMID: 26314883     DOI: 10.5603/KP.a2015.0068

Source DB:  PubMed          Journal:  Kardiol Pol        ISSN: 0022-9032            Impact factor:   3.108


  5 in total

Review 1.  Efficacy and Safety of Transcatheter Aortic Valve Implantation for Bicuspid Aortic Valves: A Systematic Review and Meta-Analysis.

Authors:  Xiaochuan Xie; Xiaohan Shi; Xiaoshuang Xun; Li Rao
Journal:  Ann Thorac Cardiovasc Surg       Date:  2016-04-20       Impact factor: 1.520

2.  Transcatheter bicuspid aortic valve replacement in Turner syndrome: A unique experience of interventional cardiologist.

Authors:  Ahmad Munir; Ahsan Wahab; Mahin Khan; Hafiz Khan; Wah Wah Htun; Theodore L Schreiber
Journal:  J Cardiol Cases       Date:  2017-10-05

3.  Patients With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Yi Zhang; Tian-Yuan Xiong; Yi-Ming Li; Yi-Jun Yao; Jing-Jing He; Hao-Ran Yang; Zhong-Kai Zhu; Fei Chen; Yuanweixiang Ou; Xi Wang; Qi Liu; Xi Li; Yi-Jian Li; Yan-Biao Liao; Fang-Yang Huang; Zhen-Gang Zhao; Qiao Li; Xin Wei; Yong Peng; Sen He; Jia-Fu Wei; Wen-Xia Zhou; Ming-Xia Zheng; Yun Bao; Xuan Zhou; Hong Tang; Wei Meng; Yuan Feng; Mao Chen
Journal:  Front Cardiovasc Med       Date:  2022-03-16

4.  Quantitative estimation of aortic valve calcification in multislice computed tomography in predicting the development of paravalvular leaks following transcatheter aortic valve replacement.

Authors:  Małgorzata Ryś; Tomasz Hryniewiecki; Ilona Michałowska; Patrycjusz Stokłosa; Monika Różewicz-Juraszek; Zbigniew Chmielak; Maciej Dąbrowski; Kryspin Mirota; Piotr Szymański
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-03-22       Impact factor: 1.426

5.  Infective endocarditis post-transcatheter aortic valve implantation (TAVI), microbiological profile and clinical outcomes: A systematic review.

Authors:  Adnan Khan; Aqsa Aslam; Khawar Naeem Satti; Sana Ashiq
Journal:  PLoS One       Date:  2020-01-17       Impact factor: 3.240