Comparative effectiveness and safety of image guidance systems in surgery: a preclinical randomised study.

Hani J Marcus1, Philip Pratt2, Archie Hughes-Hallett2, Thomas P Cundy2, Adam P Marcus3, Guang-Zhong Yang2, Ara Darzi2, Dipankar Nandi4.   

Abstract

BACKGROUND: Over the past decade image guidance systems have been widely adopted in specialties such as neurosurgery and otorhinolaryngology. Nonetheless, the evidence supporting the use of image guidance systems in surgery remains limited. New augmented reality systems offer the possibility of enhanced operating room workflow compared with existing triplanar image displays, but recent studies have highlighted several concerns, particularly the risk of inattentional blindness and impaired depth perception. The aim of this study was to compare simultaneously the effectiveness and safety of various image guidance systems against standard surgery.
METHODS: In this preclinical randomised study design 50 novice surgeons were allocated to no image guidance, triplanar display, always-on solid overlay, always-on wire mesh overlay, or on-demand inverse realism overlay. Each participant was asked to identify a basilar tip aneurysm in a validated model head. The primary outcomes were time to task completion, and tool path length. The secondary outcomes were recognition of an unexpected finding (a surgical clip) and subjective depth perception (using a Likert scale).
FINDINGS: Surgeons' time to task completion and tool path length were significantly lower in groups using any form of image guidance than in groups with no image guidance (p<0·001 and p=0·003, respectively). The tool path distance was also lower in groups using augmented reality than in those using triplanar display (p=0·010). Always-on solid overlay resulted in the greatest inattentional blindness (20% recognition of unexpected finding by all surgeons). Wire mesh and on-demand overlays mitigated but did not negate inattentional blindness, and were comparable with triplanar display (40% recognition of unexpected finding in all groups). Wire mesh and inverse realism overlays also resulted in better subjective depth perception than always-on solid overlay (p=0·031 and p=0·008, respectively).
INTERPRETATION: This study suggests that new augmented reality platforms incorporating always-on wire mesh and on-demand inverse realism might improve surgical performance, at least in novice surgeons. All image display modalities, including existing triplanar display, carry a risk of inattentional blindness. FUNDING: Wellcome Trust.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Year:  2015        PMID: 26312886     DOI: 10.1016/S0140-6736(15)60379-8

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  2 in total

Review 1.  Review and Future/Potential Application of Mixed Reality Technology in Orthopaedic Oncology.

Authors:  Kwok Chuen Wong; Yan Edgar Sun; Shekhar Madhukar Kumta
Journal:  Orthop Res Rev       Date:  2022-05-16

Review 2.  Enhanced Visualization: From Intraoperative Tissue Differentiation to Augmented Reality.

Authors:  Dirk Wilhelm; Thomas Vogel; Daniel Ostler; Nils Marahrens; Nils Kohn; Sebastian Koller; Helmut Friess; Michael Kranzfelder
Journal:  Visc Med       Date:  2018-02-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.