Abstract

Until recently, multiple solid-phase microextraction fibers could not be automatically desorbed in a single gas chromatographic sequence without manual intervention from an operator. This drawback had been a critical issue, particularly during the analysis of numerous on-site samples taken with various fiber assemblies. Recently, a Multi-Fiber Exchange system, designed to overcome this flaw found in other commercially available autosamplers, was released. In the current research, a critical evaluation of the Multi-Fiber Exchange system performance in terms of storage stability and long-term operation is presented. It was established in the course of our research that the Multi-Fiber Exchange system can operate continuously and precisely for multiple extraction/injection cycles. However, when the effect of residence time of commercial fibers on the Multi-Fiber Exchange tray was evaluated, results showed that among the evaluated fiber coatings, Carboxen/polydimethylsiloxane was the only coating capable of efficient storage on the tray for up to 24 h after field sampling without suffering significant loss of analytes (≤10% for benzene, toluene, ethylbenzene, o-xylene, decane, and limonene). Additionally, the system capability for high-throughput analysis was demonstrated by the unattended desorption of multiple fibers after on-site sampling of toluene, indoor air levels, in a polymer synthesis lab.
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Automated solid-phase microextraction; Multifiber exchange system; On-site analysis; SPME

Year:  2015        PMID: 26311558     DOI: 10.1002/jssc.201500158

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  2 in total

1.  A Small Footprint and Robust Interface for Solid Phase Microextraction and Mass Spectrometry Based on Vibrating Sharp-Edge Spray Ionization.

Authors:  Jing Wang; Chong Li; Peng Li
Journal:  J Am Soc Mass Spectrom       Date:  2022-01-18       Impact factor: 3.262

2.  Innovative Monitoring of Atmospheric Gaseous Hydrogen Fluoride.

Authors:  Stefano Dugheri; Alessandro Bonari; Ilenia Pompilio; Alessandro Monti; Nicola Mucci; Giulio Arcangeli
Journal:  Int J Anal Chem       Date:  2016-10-13       Impact factor: 1.885

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.