Effects of inflow velocity profile on two-dimensional hemodynamic analysis by ordinary and ultrasonic-measurement-integrated simulations.

Takaumi Kato1, Shusaku Sone1, Kenichi Funamoto2, Toshiyuki Hayase3, Hiroko Kadowaki4, Nobuyuki Taniguchi5.   

Abstract

Two-dimensional ultrasonic-measurement-integrated (2D-UMI) simulation correctly reproduces hemodynamics even with an inexact inflow velocity distribution. This study aimed to investigate which is superior, a two-dimensional ordinary (2D-O) simulation with an accurate inflow velocity distribution or a 2D-UMI simulation with an inaccurate one. 2D-O and 2D-UMI simulations were performed for blood flow in a carotid artery with four upstream velocity boundary conditions: a velocity profile with backprojected measured Doppler velocities (condition A), and velocity profiles with a measured Doppler velocity distribution, a parabolic one, and a uniform one, magnitude being obtained by inflow velocity estimation (conditions B, C, and D, respectively). The error of Doppler velocity against the measurement data was sensitive to the inflow velocity distribution in the 2D-O simulation, but not in the 2D-UMI simulation with the inflow velocity estimation. Among the results in conditions B, C, and D, the error in the worst 2D-UMI simulation with condition D was 31 % of that in the best 2D-O simulation with condition B, implying the superiority of the 2D-UMI simulation with an inaccurate inflow velocity distribution over the 2D-O simulation with an exact one. Condition A resulted in a larger error than the other conditions in both the 2D-O and 2D-UMI simulations.

Keywords:  Computational fluid dynamics; Hemodynamics; Measurement-integrated simulation; Ultrasound color Doppler imaging; Upstream boundary condition

Mesh:

Year:  2015        PMID: 26307203     DOI: 10.1007/s11517-015-1376-6

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  16 in total

Review 1.  Image-based computational fluid dynamics modeling in realistic arterial geometries.

Authors:  David A Steinman
Journal:  Ann Biomed Eng       Date:  2002-04       Impact factor: 3.934

2.  Inlet conditions for image-based CFD models of the carotid bifurcation: is it reasonable to assume fully developed flow?

Authors:  Keri R Moyle; Luca Antiga; David A Steinman
Journal:  J Biomech Eng       Date:  2006-06       Impact factor: 2.097

3.  Numerical experiment for ultrasonic-measurement-integrated simulation of three-dimensional unsteady blood flow.

Authors:  Kenichi Funamoto; Toshiyuki Hayase; Yoshifumi Saijo; Tomoyuki Yambe
Journal:  Ann Biomed Eng       Date:  2008-05-28       Impact factor: 3.934

4.  Carotid bifurcation hemodynamics in older adults: effect of measured versus assumed flow waveform.

Authors:  Yiemeng Hoi; Bruce A Wasserman; Edward G Lakatta; David A Steinman
Journal:  J Biomech Eng       Date:  2010-07       Impact factor: 2.097

5.  Development and feasibility study of a two-dimensional ultrasonic-measurement-integrated blood flow analysis system for hemodynamics in carotid arteries.

Authors:  Takaumi Kato; Kenichi Funamoto; Toshiyuki Hayase; Shusaku Sone; Hiroko Kadowaki; Tadashi Shimazaki; Takao Jibiki; Koji Miyama; Lei Liu
Journal:  Med Biol Eng Comput       Date:  2014-09-06       Impact factor: 2.602

6.  On the shape of the common carotid artery with implications for blood velocity profiles.

Authors:  Amir Manbachi; Yiemeng Hoi; Bruce A Wasserman; Edward G Lakatta; David A Steinman
Journal:  Physiol Meas       Date:  2011-10-27       Impact factor: 2.833

7.  Outflow conditions for image-based hemodynamic models of the carotid bifurcation: implications for indicators of abnormal flow.

Authors:  Umberto Morbiducci; Diego Gallo; Diana Massai; Filippo Consolo; Raffaele Ponzini; Luca Antiga; Cristina Bignardi; Marco A Deriu; Alberto Redaelli
Journal:  J Biomech Eng       Date:  2010-09       Impact factor: 2.097

8.  Effect of common carotid artery inlet length on normal carotid bifurcation hemodynamics.

Authors:  Yiemeng Hoi; Bruce A Wasserman; Edward G Lakatta; David A Steinman
Journal:  J Biomech Eng       Date:  2010-12       Impact factor: 2.097

9.  Choice of in vivo versus idealized velocity boundary conditions influences physiologically relevant flow patterns in a subject-specific simulation of flow in the human carotid bifurcation.

Authors:  Amanda K Wake; John N Oshinski; Allen R Tannenbaum; Don P Giddens
Journal:  J Biomech Eng       Date:  2009-02       Impact factor: 2.097

10.  Numerical experiment of transient and steady characteristics of ultrasonic-measurement-integrated simulation in three-dimensional blood flow analysis.

Authors:  Kenichi Funamoto; Toshiyuki Hayase; Yoshifumi Saijo; Tomoyuki Yambe
Journal:  Ann Biomed Eng       Date:  2008-11-15       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.