Literature DB >> 26306573

Development and Validation of HPLC and HPTLC Methods for Determination of Cefoperazone and Its Related Impurities.

Eglal A Abdelaleem1, Ibrahim A Naguib2, Hala E Zaazaa3, Essraa A Hussein4.   

Abstract

Validated sensitive and highly selective methods were developed for the quantitative determination of cefoperazone sodium (CEF) in the presence of its reported impurities; 7-aminocephalosporanic acid (7-ACA) and 5-mercapto-1-methyl-tetrazole (5-MER). Method A is high-performance liquid chromatography (HPLC), where the mixture of CEF and the reported impurities; 7-ACA and 5-MER were separated on a C8 column (5 µm ps, 250 mm × 4.6 i.d.) using methanol:0.05 M KH2PO4 buffer (22.5:77.5 v/v, pH 7.5) as a mobile phase. The three components were detected at 254 nm with a concentration range of 10-90 µg mL(-1) and the mean percentage recovery 99.67% (SD 1.465). Method B is high-performance thin layer chromatography (HPTLC), where the mixture of CEF and the reported impurities were separated on silica gel HPTLC F254 plates using (acetone:methanol:ethyl acetate:2% sodium lauryl sulfate:glacial acetic acid) (3:2:3:0.8:0.2, by volume) as a developing system and scanning at 254 nm over a concentration range of 1-10 µg per band with the mean percentage recovery 99.95% (SD 1.335). The proposed methods were statistically compared with a reported HPLC method with no significant difference regarding accuracy and precision; indicating the ability of the proposed methods to be reliable and suitable for routine analysis of drug product. The proposed HPTLC method proved to be more sensitive, while the HPLC gave more reproducible results besides saving time.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26306573     DOI: 10.1093/chromsci/bmv125

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  2 in total

1.  Determination of Cefoperazone Sodium in Presence of Related Impurities by Linear Support Vector Regression and Partial Least Squares Chemometric Models.

Authors:  Ibrahim A Naguib; Eglal A Abdelaleem; Hala E Zaazaa; Essraa A Hussein
Journal:  J Anal Methods Chem       Date:  2015-11-19       Impact factor: 2.193

2.  Development of a high-precision bladder hyperthermic intracavitary chemotherapy device for bladder cancer and pharmacokinetic study.

Authors:  Mingchen Ba; Shuzhong Cui; Hui Long; Yuanfeng Gong; Yinbing Wu; Kunpeng Lin; Yinuo Tu; Bahuo Zhang; Wanbo Wu
Journal:  BMC Urol       Date:  2019-12-03       Impact factor: 2.264

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.