Literature DB >> 26306307

Percutaneous Forceps Retrieval of an Embolized Amplatzer Duct Occluder.

Yi-Sik Kim1, Sang-Rok Lee1.   

Abstract

Transcatheter closure of patent ductus arteriosus with the Amplatzer duct occluder shows excellent results. However, there is a risk of device embolization after deployment. We report the case of a 33-year-old man in whom an embolized Amplatzer device was retrieved from the right pulmonary artery by a percutaneous method. We also review this uncommon severe complication and offer technical tips for percutaneous removal.

Entities:  

Keywords:  Ductus arteriosus; Patent; Septal occluder device

Year:  2015        PMID: 26306307      PMCID: PMC4543149          DOI: 10.4068/cmj.2015.51.2.106

Source DB:  PubMed          Journal:  Chonnam Med J        ISSN: 2233-7393


  6 in total

Review 1.  Transcatheter closure of patent ductus arteriosus: past, present and future.

Authors:  Alban-Elouen Baruteau; Sébastien Hascoët; Julien Baruteau; Younes Boudjemline; Virginie Lambert; Claude-Yves Angel; Emre Belli; Jérôme Petit; Robert Pass
Journal:  Arch Cardiovasc Dis       Date:  2014-02-20       Impact factor: 2.340

2.  The Amplatzer duct occluder: experience in 209 patients.

Authors:  A A Bilkis; M Alwi; S Hasri; A L Haifa; K Geetha; M A Rehman; I Hasanah
Journal:  J Am Coll Cardiol       Date:  2001-01       Impact factor: 24.094

3.  Multicenter USA Amplatzer patent ductus arteriosus occlusion device trial: initial and one-year results.

Authors:  Robert H Pass; Ziyad Hijazi; Daphne T Hsu; Veronica Lewis; William E Hellenbrand
Journal:  J Am Coll Cardiol       Date:  2004-08-04       Impact factor: 24.094

4.  Transcatheter retrieval of embolized AMPLATZER Septal Occluder.

Authors:  Pravin K Goel; Aditya Kapoor; Aditya Batra; Roopali Khanna
Journal:  Tex Heart Inst J       Date:  2012

5.  Embolization and retrieval of the Amplatzer septal occluder.

Authors:  Daniel S Levi; John W Moore
Journal:  Catheter Cardiovasc Interv       Date:  2004-04       Impact factor: 2.692

6.  The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome.

Authors:  W Boehm; M Emmel; N Sreeram
Journal:  Images Paediatr Cardiol       Date:  2007-04
  6 in total
  1 in total

1.  Surgical removal of part of an occluder to treat iatrogenic coarctation of the aorta: a case report.

Authors:  Zhongwei Sun; Dongxu Li; Yabo Wang; Qi An
Journal:  BMC Surg       Date:  2020-01-17       Impact factor: 2.102

  1 in total