Literature DB >> 26303400

Informing a realistic laboratory erosion-testing regime--observations.

A S Qutieshat1, A G Mason2, R G Chadwick3.   

Abstract

OBJECTIVES: To measure aspects of fizzy drink consumption in a social environment to inform the development of a laboratory testing regime.
METHODS: This was an observational study in which participants were invited to attend one of four pizza and soft drink parties. All such foods and drinks were served in an air conditioned room at a temperature of 24°C. All drinks were at a temperature of 4°C and each participant was asked to spit out, into graduated cups, their first and second sips. Both the temperature and volume of these were measured. Upon completion of the party the volume of drinks consumed was determined. Video footage of the experiment was recorded for subsequent analysis to determine sip count and the elapsed time period between first and last sip. These values were compared to the analogous measured value of expectorated volume in order to assess the usefulness of video observation in the context of this work.
RESULTS: The mean expectorated beverage temperature was 14.9±2.0°C. The mean time spent drinking was 44.2±17.4 minutes with a mean consumption rate of 13.3±6.0 ml/min. Only the sip volume and sip count per can values were significantly different between sexes (P<0.05) with females displaying lower values for volume and a higher sip count. There was close agreement between the sip volume values observed and calculated using video observation derived parameters.
CONCLUSIONS: Several human drinking behaviour values were reported in this study and these will be of value in the development of more realistic laboratory erosion-testing regimes. It is concluded, within the limitations of this work, that (1) there are differences in the drinking behaviour of males and females with respect to sip volume and count, (2) the intraoral rise in temperature of a 4°C beverage is lower than that used in previous laboratory simulations and (3) the values derived from video observation agree with those measured directly validating this technique for use in further studies. CLINICAL SIGNIFICANCE: The work provides valuable quantitative data on which to base simulated laboratory erosion work. Perhaps the most significant finding is that sipped beverages attain a temperature of only 14.9°C.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Behaviour; Carbonated beverages; Erosion; Observation

Mesh:

Year:  2015        PMID: 26303400     DOI: 10.1016/j.jdent.2015.08.008

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  1 in total

1.  In vitro simulation of erosive challenges to human enamel using a novel artificial mouth.

Authors:  Abubaker S Qutieshat; Andrew Graham Mason; Richard Graham Chadwick
Journal:  Clin Exp Dent Res       Date:  2018-06-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.