Literature DB >> 26301533

Production of scandium-44 m and scandium-44 g with deuterons on calcium-44: cross section measurements and production yield calculations.

C Duchemin1, A Guertin, F Haddad, N Michel, V Métivier.   

Abstract

HIGHLIGHTS • Production of Sc-44 m, Sc-44 g and contaminants. • Experimental values determined using the stacked-foil technique. • Thick-Target production Yield (TTY) calculations. • Comparison with the TALYS code version 1.6.Among the large number of radionuclides of medical interest, Sc-44 is promising for PET imaging. Either the ground-state Sc-44 g or the metastable-state Sc-44 m can be used for such applications, depending on the molecule used as vector. This study compares the production rates of both Sc-44 states, when protons or deuterons are used as projectiles on an enriched Calcium-44 target. This work presents the first set of data for the deuteron route. The results are compared with the TALYS code. The Thick-Target production Yields of Sc-44 m and Sc-44 g are calculated and compared with those for the proton route for three different scenarios: the production of Sc-44 g for conventional PET imaging, its production for the new 3 γ imaging technique developed at the SUBATECH laboratory and the production of a Sc-44 m/Sc-44 g in vivo generator for antibody labelling.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26301533     DOI: 10.1088/0031-9155/60/17/6847

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Developments toward the Implementation of 44Sc Production at a Medical Cyclotron.

Authors:  Nicholas P van der Meulen; Roger Hasler; Zeynep Talip; Pascal V Grundler; Chiara Favaretto; Christoph A Umbricht; Cristina Müller; Gaia Dellepiane; Tommaso S Carzaniga; Saverio Braccini
Journal:  Molecules       Date:  2020-10-14       Impact factor: 4.411

Review 2.  Production of scandium radionuclides for theranostic applications: towards standardization of quality requirements.

Authors:  R Mikolajczak; S Huclier-Markai; C Alliot; F Haddad; D Szikra; V Forgacs; P Garnuszek
Journal:  EJNMMI Radiopharm Chem       Date:  2021-05-25

3.  Is 70Zn(d,x)67Cu the Best Way to Produce 67Cu for Medical Applications?

Authors:  Etienne Nigron; Arnaud Guertin; Ferid Haddad; Thomas Sounalet
Journal:  Front Med (Lausanne)       Date:  2021-07-05

4.  Cyclotron production of (43)Sc for PET imaging.

Authors:  Rafał Walczak; Seweryn Krajewski; Katarzyna Szkliniarz; Mateusz Sitarz; Kamel Abbas; Jarosław Choiński; Andrzej Jakubowski; Jerzy Jastrzębski; Agnieszka Majkowska; Federica Simonelli; Anna Stolarz; Agnieszka Trzcińska; Wiktor Zipper; Aleksander Bilewicz
Journal:  EJNMMI Phys       Date:  2015-12-04

Review 5.  Dual Probes for Positron Emission Tomography (PET) and Fluorescence Imaging (FI) of Cancer.

Authors:  Richard Yuen; Frederick G West; Frank Wuest
Journal:  Pharmaceutics       Date:  2022-03-15       Impact factor: 6.321

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.