Literature DB >> 26299256

Ultrasonography of the optic nerve sheath to assess intracranial pressure changes after ventriculo-peritoneal shunt surgery in children with hydrocephalus: a prospective observational study.

S-H Choi1, K-T Min1, E-K Park2, M-S Kim1, J-H Jung3, H Kim3.   

Abstract

The optic nerve sheath diameter has been verified by various clinical studies as a non-invasive indicator of intracranial hypertension. The aim of this study was to compare the optic nerve sheath diameter before and immediately after ventriculo-peritoneal shunt surgery in children with hydrocephalus. We analysed transorbital ultrasonographic images recorded after induction of anaesthesia and 30 min after shunt insertion in 34 children, measuring the optic nerve sheath diameters using a linear ultrasound probe. The mean (SD) optic nerve sheath diameters were 5.4 (0.6) mm (right) and 5.3 (0.7) mm (left) before surgery and 4.4 (0.5) mm (right) and 4.5 (0.7) mm (left) after surgery (p < 0.0001 for before and after comparisons for both eyes). The technique allows rapid and non-invasive assessment of intracranial pressure to guide appropriate postoperative management.
© 2015 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2015        PMID: 26299256     DOI: 10.1111/anae.13180

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  8 in total

1.  Use of neuroimaging measurements of optic nerve sheath diameter to assess intracranial pressure in craniosynostosis.

Authors:  Mostafa Haredy; Giulio Zuccoli; Mandeep Tamber; Amani Davis; Ken Nischal; Jesse A Goldstein
Journal:  Childs Nerv Syst       Date:  2018-01-29       Impact factor: 1.475

2.  Quantitative Evans index estimation using ultrasonographic measurement of the optic nerve sheath diameter in supine and upright position.

Authors:  Mindaugas Urbonas; Nijole Raskauskiene; Vytenis Deltuva; Adomas Bunevicius
Journal:  Acta Neurochir (Wien)       Date:  2022-05-21       Impact factor: 2.816

3.  Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery.

Authors:  Akhilendra Chopra; Praveen K Das; Samiksha Parashar; Shilpi Misra; Manoj Tripathi; Deepak Malviya; Deepak Singh
Journal:  Cureus       Date:  2022-05-22

4.  Patient management algorithm combining processed electroencephalographic monitoring with cerebral and somatic near-infrared spectroscopy: a case series.

Authors:  Etienne J Couture; Alain Deschamps; André Y Denault
Journal:  Can J Anaesth       Date:  2019-02-01       Impact factor: 5.063

5.  The incidence of increased ICP in ICU patients with non-traumatic coma as diagnosed by ONSD and CT: a prospective cohort study.

Authors:  Nawal Salahuddin; Alaa Mohamed; Nadia Alharbi; Hamad Ansari; Khaled J Zaza; Qussay Marashly; Iqbal Hussain; Othman Solaiman; Torbjorn V Wetterberg; Khalid Maghrabi
Journal:  BMC Anesthesiol       Date:  2016-10-25       Impact factor: 2.217

6.  The assessment of the effect of different intraabdominal pressures used for laparoscopic cholecystectomy surgery on optic nerve sheath diameter: a prospective observational cohort study

Authors:  Tuna Ertürk; Bülent Barış Güven; Yadigar Yılmaz; Fulya Yurtsever; Ayşın Ersoy
Journal:  Turk J Med Sci       Date:  2021-06-28       Impact factor: 0.973

Review 7.  Ultrasonic measurement of optic nerve sheath diameter: a non-invasive surrogate approach for dynamic, real-time evaluation of intracranial pressure.

Authors:  Li-Min Chen; Li-Juan Wang; Yang Hu; Xiao-Han Jiang; Yu-Zhi Wang; Ying-Qi Xing
Journal:  Br J Ophthalmol       Date:  2018-10-25       Impact factor: 4.638

8.  Epidural bolus versus continuous epidural infusion analgesia on optic nerve sheath diameter in paediatric patients: A prospective, double-blind, randomised trial.

Authors:  Bora Lee; Jae Hoon Lee; Min-Soo Kim; Seon Ju Kim; Jeehyun Song; Do-Hyeong Kim; Yong Seon Choi
Journal:  Sci Rep       Date:  2020-03-25       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.