Literature DB >> 26299216

Randomized comparison of a sirolimus-eluting Orsiro stent with a biolimus-eluting Nobori stent in patients treated with percutaneous coronary intervention: Rationale and study design of the Scandinavian Organization for Randomized Trials with Clinical Outcome VII trial.

Lisette Okkels Jensen1, Per Thayssen2, Michael Maeng3, Jan Ravkilde4, Henrik Steen Hansen2, Svend Eggert Jensen4, Hans Erik Bøtker3, Klára Berencsi5, Jens Flensted Lassen3, Evald Høj Christiansen3.   

Abstract

BACKGROUND: Third-generation coronary drug-eluting stents (DES) with biodegradable polymers have been designed to improve safety and efficacy. We designed a large scale registry-based randomized clinical trial to compare 2 third-generation DES: a thin strut, cobalt-chromium DES with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the stainless steel biodegradable polymer biolimus-eluting Nobori stents (N-BES, Nobori; Terumo, Tokyo, Japan) in an all-comer patient population.
DESIGN: The multicenter SORT OUT VII trial (NCT01879358) randomly assigned 2,530 patients to treatment with biodegradable polymer O-SES or biodegradable polymer N-BES at 3 sites in Western Denmark. Patients were eligible, if they were ≥18 years old; had chronic stable coronary artery disease or acute coronary syndromes; and ≥1 coronary lesion with >50% diameter stenosis, requiring treatment with a DES. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically, driven event detection based on Danish registries will be used. An event rate of 6.5% is assumed in each stent group. With a sample size of 1,157 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the O-SES compared with the N-BES with a predetermined noninferiority margin of 3.0%.
CONCLUSION: The SORT OUT VII trial will determine whether the biodegradable polymers O-SES is noninferior to the N-BES with respect to driven event.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26299216     DOI: 10.1016/j.ahj.2015.05.009

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  3 in total

1.  Culotte versus the novel nano-crush technique for unprotected complex bifurcation left main stenting: difference in procedural time, contrast volume and X-ray exposure and 3-years outcomes.

Authors:  Gianluca Rigatelli; Marco Zuin; Dobrin Vassilev; Huy Dinh; Sara Giatti; Mauro Carraro; Francesco Zanon; Loris Roncon; Ho Thuong Dung
Journal:  Int J Cardiovasc Imaging       Date:  2018-11-16       Impact factor: 2.357

2.  Linkage of clinical trial and administrative data: a survey of cancer patient preferences.

Authors:  A E Hay; Y W Leung; J L Pater; M C Brown; E Bell; D Howell; Z Kassam; S Willing; C Tian; G Liu
Journal:  Curr Oncol       Date:  2017-06-27       Impact factor: 3.677

Review 3.  Drug-Eluting Stents and Balloons-Materials, Structure Designs, and Coating Techniques: A Review.

Authors:  I Rykowska; I Nowak; R Nowak
Journal:  Molecules       Date:  2020-10-11       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.