BACKGROUND: Studies examining vitamin E intake and the percentage of the population meeting dietary guidelines do not distinguish between natural (RRR-α-tocopherol) and synthetic (all-rac-α-tocopherol) intake, even though these different isomeric forms differ in bioactivity. OBJECTIVE: This study aimed to determine the effect of RRR-α-tocopherol vs. all-rac-α-tocopherol intake on the percentage of the population meeting the vitamin E recommendation and on plasma α-tocopherol stereoisomer distribution. METHODS: With the use of data from the Irish National Adult Nutrition Survey (NANS), this study examined the percentage of the Irish population meeting the European Union (EU) RDA for vitamin E of 12 mg/d, correcting for a bioactivity difference in all-rac- vs. RRR-α-tocopherol, where 1 mg of all-rac-α-tocopherol is considered to be equivalent to 1:1.36 (0.74) mg in the EU RDA. In a subcohort of supplement users and nonusers, plasma α- and γ-tocopherol concentrations and α-tocopherol stereoisomer distribution were measured. Receiver operating characteristic (ROC) curve analysis was conducted to determine ability to discriminate supplement user types. RESULTS: Analysis of the NANS showed that 100% of participants still met the recommended intake of 12 mg/d, after all-rac-α-tocopherol intake was corrected for α-tocopherol equivalent bioactivity. In the subcohort analysis, the percentage of plasma RRR-α-tocopherol was significantly lower in high all-rac-α-tocopherol supplement (>11 mg/d) users (82%) compared with nonusers and with high RRR-α-tocopherol supplement (>35 mg/d) users (91% and 93% respectively, P < 0.01). High RRR-α-tocopherol supplement users had a significantly higher plasma α-tocopherol than low all-rac-α-tocopherol supplement (<2.5 mg/d) users (34 vs. 25 μmol/L, P = 0.01). ROC analysis demonstrated an ability to distinguish between RRR- and all-rac-α-tocopherol consumers, which may be useful in investigating the potential effect of RRR- and all-rac-α-tocopherol intake on health. CONCLUSIONS: This study demonstrated that the percentage of the population meeting the vitamin E recommendation was unaffected when all-rac-α-tocopherol intake was corrected for α-tocopherol equivalent bioactivity. all-rac-α-Tocopherol intake led to a decrease in the percentage of plasma RRR-α-tocopherol relative to RRR-α-tocopherol intake.
BACKGROUND: Studies examining vitamin E intake and the percentage of the population meeting dietary guidelines do not distinguish between natural (RRR-α-tocopherol) and synthetic (all-rac-α-tocopherol) intake, even though these different isomeric forms differ in bioactivity. OBJECTIVE: This study aimed to determine the effect of RRR-α-tocopherol vs. all-rac-α-tocopherol intake on the percentage of the population meeting the vitamin E recommendation and on plasma α-tocopherol stereoisomer distribution. METHODS: With the use of data from the Irish National Adult Nutrition Survey (NANS), this study examined the percentage of the Irish population meeting the European Union (EU) RDA for vitamin E of 12 mg/d, correcting for a bioactivity difference in all-rac- vs. RRR-α-tocopherol, where 1 mg of all-rac-α-tocopherol is considered to be equivalent to 1:1.36 (0.74) mg in the EU RDA. In a subcohort of supplement users and nonusers, plasma α- and γ-tocopherol concentrations and α-tocopherol stereoisomer distribution were measured. Receiver operating characteristic (ROC) curve analysis was conducted to determine ability to discriminate supplement user types. RESULTS: Analysis of the NANS showed that 100% of participants still met the recommended intake of 12 mg/d, after all-rac-α-tocopherol intake was corrected for α-tocopherol equivalent bioactivity. In the subcohort analysis, the percentage of plasma RRR-α-tocopherol was significantly lower in high all-rac-α-tocopherol supplement (>11 mg/d) users (82%) compared with nonusers and with high RRR-α-tocopherol supplement (>35 mg/d) users (91% and 93% respectively, P < 0.01). High RRR-α-tocopherol supplement users had a significantly higher plasma α-tocopherol than low all-rac-α-tocopherol supplement (<2.5 mg/d) users (34 vs. 25 μmol/L, P = 0.01). ROC analysis demonstrated an ability to distinguish between RRR- and all-rac-α-tocopherol consumers, which may be useful in investigating the potential effect of RRR- and all-rac-α-tocopherol intake on health. CONCLUSIONS: This study demonstrated that the percentage of the population meeting the vitamin E recommendation was unaffected when all-rac-α-tocopherol intake was corrected for α-tocopherol equivalent bioactivity. all-rac-α-Tocopherol intake led to a decrease in the percentage of plasma RRR-α-tocopherol relative to RRR-α-tocopherol intake.
Authors: Aoibheann M McMorrow; Ruth M Connaughton; Tiago R Magalhães; Fiona C McGillicuddy; Maria F Hughes; David Cheishvili; Melissa J Morine; Sean Ennis; Marie-Louise Healy; Edna F Roche; Richard E Tremblay; Moshe Szyf; Fiona E Lithander; Helen M Roche Journal: Mol Nutr Food Res Date: 2018-05 Impact factor: 5.914
Authors: Rafaella Cristhine Pordeus Luna; Mayara Karla Dos Santos Nunes; Mussara Gomes Cavalcante Alves Monteiro; Cássia Surama Oliveira da Silva; Rayner Anderson Ferreira do Nascimento; Raquel Patrícia Ataíde Lima; Flávia Cristina Fernandes Pimenta; Naila Francis Paulo de Oliveira; Darlene Camati Persuhn; Aléssio Tony Cavalcanti de Almeida; Alcides da Silva Diniz; Cristina Wide Pissetti; Rodrigo Pinheiro Toledo Vianna; Flavia Emília Leite de Lima Ferreira; Maria da Conceição Rodrigues Gonçalves; Maria José de Carvalho Costa Journal: Nutr Metab (Lond) Date: 2018-07-11 Impact factor: 4.169