Evaluation of the effects of three different mouthwashes on the force decay of orthodontic chains.

Maryam Omidkhoda1, Roozbeh Rashed2, Neda Khodarahmi3.   

Abstract

BACKGROUND: Elastomeric chains are commonly used in orthodontics. Force decay in these materials poses clinical problems. The aim of this study was to evaluate the effects of three different mouthwashes on the force decay of orthodontic chains.
MATERIALS AND METHODS: In this experimental study, elastomeric chains with two different configurations were divided into eight groups (two control and six test groups). After 10 s of prestretching up to 100% of their initial length, the chains were stretched for 25 mm on jig pins and then immersed in artificial saliva, persica, chlorhexidine 0.2% and sodium fluoride 0.05% mouthwashes. Ten cycles of thermocycling between 5°C and 55°C were conducted daily during the test period. In order to reach a 200-g initial force, seven loop closed chains, and five-loop short chains were selected. Forces were recorded by digital force gauge (Lutron) at initial, 24 h, 1, 2, 3 and 4 weeks for all groups. The amount of force loss was compared among different mouthwashes and times using one-way analysis of variance (post-hoc, Tukey, α = 0.05).
RESULTS: About 20% of the force decay occurred during the first 24 h, but after that and up to the 4(th) week the rate of force loss was gradual and steady. After 4 weeks, persica and chlorhexidine caused the lowest and the highest percentage of force loss, respectively. These two mouthwashes showed statistically significant differences at all points of time (P < 0.05).
CONCLUSION: Within the limitations of this study, during the orthodontic treatment, persica is preferred to chlorhexidine for oral health control.

Entities:  

Keywords:  Elastomeric chain; force decay; mouthwash

Year:  2015        PMID: 26288625      PMCID: PMC4533193          DOI: 10.4103/1735-3327.161453

Source DB:  PubMed          Journal:  Dent Res J (Isfahan)        ISSN: 1735-3327


INTRODUCTION

Elastomeric products are used as ligatures and chains in order to apply retraction forces to the teeth.[1] Since 1960s, elastomeric chains have entered orthodontic treatment[2] and for some applications, have replaced elastic appliances. The latter are made of latex, and the patient has to replace them daily. In addition, orthodontists prefer elastomeric ligatures to stainless steel wire ligatures.[1] Not only have the elastomeric chains the ability to return to their original shape after some deformation, but also they are easy to use, relatively hygienic, economical and do not need patient compliance.[2] In spite of this acceptability, there has always been a concern about force degradation in these elastomeric materials. This has led to an increasing interest toward self-ligating brackets that eliminates the need for elastomeric ligatures. One of the most important reasons of plastic deformation and force decay of elastomeric modules is their sensitivity to the changes in intraoral environment that arise from a number of factors including different foods and beverages and other materials that enter the oral cavity.[34] Mouthwashes have been used for centuries for medicinal and cosmetic purposes, but it is only in recent years that the rationale behind the use of chemical ingredients has been subject to scientific research and clinical trials. Today's dentists are practicing in an era where the patients are more concerned about both their oral health and their overall medical wellbeing. Thus, in the midst of growing evidence of the connection between oral health and whole body health, herbal medicines with their “naturally occurring” active ingredients offer a gentle and enduring way for restoration of health by the most trustworthy and least harmful way.[5] Recently, the use of herbal mouthwashes such as persica is increasing. Persica is prepared from Salvadora persica extract. It has been shown that using this herbal medicine or its extract would support periodontal health, and reduces the accumulation of microbial plaques,[6] and bleeding during brushing,[78] and controls gingivitis and periodontal diseases.[789] The aim of this study was to evaluate the effects of three different mouthwashes on the force decay of orthodontic chains.

MATERIALS AND METHODS

In this study, elastomeric chains were used to simulate retraction of canine into premolar extraction space. Clear elastomeric chains (Dentaurum, Germany) in two configurations of short- and closed-connector were stored in plastic packages at room temperature (22-24°C) until the beginning of the study.[410] Each piece of short- and closed-connector chains included five and seven loops, respectively. An extra half loop at each end was reserved to compensate for the probable damage caused by prestretching and to facilitate performing the test. The chains were prestretched to 100% of their initial length for 10 s. A jig with two posts secured on it with screws was designed [Figure 1]. The distance between the posts was fixed at 25 mm to simulate the distance between the first molar hook and distal wings of the canine bracket.[1112] Each piece of chain was stretched between two posts. In this way, a constant force was exerted on elastomeric chain during the test period.
Figure 1

Jigs designed for stretching of elastomeric chains.

Jigs designed for stretching of elastomeric chains. One hundred and twenty pieces of chains were divided into two control and six experimental groups of 15 as follows: Control group 1: Short-connector chains in artificial saliva. Control group 2: Closed-connector chains in artificial saliva. Experimental group 1: Short-connector chains in chlorhexidine 0.2% mouthwash. Experimental group 2: Closed-connector chains in chlorhexidine 0. 2% mouthwash. Experimental group 3: Short-connector chains in persica mouthwash. Experimental group 4: Closed-connector chains in persica mouthwash. Experimental group 5: Short-connector chains in 0.05% sodium fluoride mouthwash. Experimental group 6: Closed-connector chains in 0.05% sodium fluoride mouthwash. Six pieces of chains (three short- and three closed-connectors) were mounted on the posts in the same manner, and their remained forces were measured. This was a time 0 and air group. All groups (except time 0) underwent thermocycling: Ten 30-s cycles/day in 5 and 55°C with 30-s for transition.[13] The chains were placed in their planned mouthwashes for 1 min/day to simulate the application of mouthwash by the patient. Then, the chains were rinsed by distilled water and returned to artificial saliva. The effects of the following three mouthwashes on the force loss were evaluated: Chlorhexidine 0.2% (Shahdaru Laboratories, Tehran, Iran) with 0.2% chlorhexidine digluconate and 13.65% ethanol (V/V), persica (Poursina Pharmaceutical Laboratories, Tehran, Iran) containing extract of S. persica (meswak), mint and yarrow extract with main ingredient as tannen, flavonid, calcium, fluoride, chloride and essence and Oral-B sodium fluoride 0.05% mouthwash (Procter and Gamble, Weybridge, United Kingdom) containing water, glycerin, alcohol, aroma, methyl paraben, poloxamer 407, cetylpyridinum chloride, sodium fluoride, sodium saccharin, propylparaben.[14] The remained force of the chains in each group was measured at time 0 (control groups) and after 24 h, 1, 2, 3 and 4 weeks by a force gauge (Lutron, model DC-515, Taiwan) [Figure 2].
Figure 2

Force gauge coupling with jig. The distance between the posts remained constant while transferring to gauge.

Force gauge coupling with jig. The distance between the posts remained constant while transferring to gauge. The two-way analysis of variance (ANOVA) of Statistical Package for the Social Sciences (SPSS) software (SPSS Inc., Chicago, IL, USA) was employed to compare the amount of force loss percentage among the groups. The level of significance (α) was set at 5%.

RESULTS

In this experimental cross-sectional-analytic study, the effects of three different mouthwashes (chlorhexidine, sodium fluoride, and persica) on the force loss of two configurations of orthodontic chains (closed and short connector) at 6 times points (0, 24 h, 1, 2, 3 and 4 weeks) were evaluated. Initially, data were studied using Kolmogorov–Smirnov statistical test to assess normal distribution. Then, two-way ANOVA and Tukey post-hoc were used to compare force degradation percentage. Results showed that the amount of force degradation percentage in both chain configurations, in all solutions including the artificial saliva, showed significant loss (P < 0.05) [Tables 1–3].
Table 1

Percentage of force decay in short- and closed-connector chains in different environments and times (compered to initial)

Table 3

A comparison between different solutions in short and closed-connector chains

Percentage of force decay in short- and closed-connector chains in different environments and times (compered to initial) A comparison between different times in short- and closed-connector chains A comparison between different solutions in short and closed-connector chains In all solutions, from the beginning to the end of week 4, significant force loss was observed in short and closed connector chains (P < 0.05), but in all situations, persica caused less force loss compared to other media.

DISCUSSION

Although elastomeric chains are widely used in orthodontics to move and close the space, force loss over time is inevitable. Several studies have examined the force degradation of elastomeric chains.[151617] Many factors influence the rate of force decay including the manufacturer of the chain, the study design (in vitro or in vivo), the shape of the chain, different environments, temperature and potential of hydrogen (pH).[15161718] There has been little research on controllable factors like the effects of mouthwashes. In this study, we evaluated the effects of three different mouthwashes on the force decay of orthodontic chains. Artificial saliva was chosen as a control group because in some studies force degradation was higher in wet than in dry environments.[192021] As changes in the temperature is an important parameter that affects the behavior of orthodontic chains,[172223] the chains were thermocycled in this study. The initial force of approximately 200-g was used because this is the force that usually is needed for distal movement of canine.[2425] The results of the current study show that both closed and short connector chains in all mouthwashes had significant force losses at all times. Almost all previous studies showed that in any test environment, the highest force loss occurred during the 1st h or the first 24 h and then progressed in a more steady and gradual rate.[161726272829] In the present study, during the first 24 h, the force loss was 21-26% and 19-27% of the initial force in short connector and in closed connector chains, respectively. At the end of week 4, 40-50% of the initial force had been lost in short connector chains. The loss was 43-60% of the initial force in closed connector chains. This range of force loss was similar to Motta et al.[30] and Buchmann et al.[31] studies. Other studies, however, showed a higher range of force loss (up to 75% of the initial force) in the first 24 h.[2728] This difference was found to be highly dependent on the experimental conditions as the force loss is higher in wet in vitro conditions than in the air or dry conditions. It has also been shown that force decay is higher in in vivo compared to wet in vitro conditions.[4161719] In this study, both chain configurations showed the lowest range of force loss when immersed in persica and had the highest force loss in chlorhexidine. This was significant in all time points. In an attempt to reconstruct the oral environment in studies on elastomeric chains, the effects of different materials with different pH, and different compositions have also been considered. The pH of <7.26 results in less force decay and contrary to the previous assumptions, more acidity do not cause higher force loss.[1532] If we note the pH of mouthwashes in the present study, persica (pH = 5.68) was more acidic than chlorhexidine (pH = 7.47). The highest force loss caused by chlorhexidine can also be attributed to its ethanol content (13.65%). The effects of alcohol in mouthwashes on molecular and structural changes of elastomeric chains and the resulting force loss have been proven.[3334] In addition, the required force for orthodontic movement of canine is 100-300 g.[26] Despite the force loss after 4 weeks, optimal force remained approximately in all mouthwashes in short connector chains group, but in closed connector chains group, only remained in persica. Some studies have investigated the effect of distance between links on the force decay.[326] Their results showed that the elastomeric chains with less distance between modules produced higher initial force and underwent less force decay.[3] In this study, the pattern was different from these results, and the force loss was greater in closed connector chains, but persica was able to reduce the force loss.

CONCLUSION

All short and closed connector elastomeric chains showed a significant range of force loss during 4 weeks. The force loss was statistically significant in artificial saliva, persica, chlorhexidine, and sodium fluoride. The largest amount of force loss occurred in the first 24 h, and it was about half of the whole force loss in 4 weeks. Chlorhexidine caused the highest force loss followed by sodium fluoride and the artificial saliva. Chains in the persica had the lowest force loss.
Table 2

A comparison between different times in short- and closed-connector chains

  30 in total

1.  Calibration of force extension and force degradation characteristics of orthodontic latex elastics.

Authors:  P Kanchana; K Godfrey
Journal:  Am J Orthod Dentofacial Orthop       Date:  2000-09       Impact factor: 2.650

2.  Effects of prestretching on force degradation of synthetic elastomeric chains.

Authors:  Kyung-Ho Kim; Chun-Hsi Chung; Kwnagchul Choy; Jeong-Sub Lee; Robert L Vanarsdall
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-10       Impact factor: 2.650

3.  The environmental influence of Light Coke, phosphoric acid, and citric acid on elastomeric chains.

Authors:  Leandro Teixeira; Betina do Rosario Pereira; Thais Gelatti Bortoly; Joao Armando Brancher; Orlando Motohiro Tanaka; Odilon Guariza-Filho
Journal:  J Contemp Dent Pract       Date:  2008-11-01

4.  Observations on the elastic behavior of a synthetic orthodontic elastomer.

Authors:  E F Huget; K S Patrick; L J Nunez
Journal:  J Dent Res       Date:  1990-02       Impact factor: 6.116

5.  Periodontal status of adult Sudanese habitual users of miswak chewing sticks or toothbrushes.

Authors:  I A Darout; J M Albandar; N Skaug
Journal:  Acta Odontol Scand       Date:  2000-02       Impact factor: 2.331

6.  Ion release from orthodontic brackets in 3 mouthwashes: an in-vitro study.

Authors:  Shahla Momeni Danaei; Afsaneh Safavi; S M Mehdi Roeinpeikar; Morteza Oshagh; Shiva Iranpour; Maryam Omidkhoda; Maryam Omidekhoda
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-06       Impact factor: 2.650

7.  The miswak (chewing stick) and oral health. Studies on oral hygiene practices of urban Saudi Arabians.

Authors:  Meshari al-Otaibi
Journal:  Swed Dent J Suppl       Date:  2004

8.  The effects of varying alcohol concentrations commonly found in mouth rinses on the force decay of elastomeric chain.

Authors:  Terrah M Larrabee; Sean Shih-Yao Liu; Ariadna Torres-Gorena; Armando Soto-Rojas; George J Eckert; Kelton T Stewart
Journal:  Angle Orthod       Date:  2012-02-06       Impact factor: 2.079

Review 9.  Thermal cycling procedures for laboratory testing of dental restorations.

Authors:  M S Gale; B W Darvell
Journal:  J Dent       Date:  1999-02       Impact factor: 4.379

10.  Influence of initial strain on the force decay of currently available elastic chains over time.

Authors:  Nora Buchmann; Christiane Senn; Judith Ball; Lorenz Brauchli
Journal:  Angle Orthod       Date:  2011-11-11       Impact factor: 2.079

View more
  1 in total

1.  The Effects of Zinc-Containing Mouthwashes on the Force Degradation of Orthodontic Elastomeric Chains: An In Vitro Study.

Authors:  Ali R Issa; Ammar S Kadhum; Shahbaa A Mohammed
Journal:  Int J Dent       Date:  2022-04-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.