Literature DB >> 26287813

Handheld-automated microsurgical instrumentation for intraocular laser surgery.

Sungwook Yang1, Louis A Lobes2, Joseph N Martel2, Cameron N Riviere1.   

Abstract

BACKGROUND AND
OBJECTIVE: Laser photocoagulation is a mainstay or adjuvant treatment for a variety of common retinal diseases. Automated laser photocoagulation during intraocular surgery has not yet been established. The authors introduce an automated laser photocoagulation system for intraocular surgery, based on a novel handheld instrument. The goals of the system are to enhance accuracy and efficiency and improve safety.
MATERIALS AND METHODS: Triple-ring patterns are introduced as a typical arrangement for the treatment of proliferative retinopathy and registered to a preoperative fundus image. In total, 32 target locations are specified along the circumferences of three rings having diameters of 1, 2, and 3 mm, with a burn spacing of 600 μm. Given the initial system calibration, the retinal surface is reconstructed using stereo vision, and the targets specified on the preoperative image are registered with the control system. During automated operation, the laser probe attached to the manipulator of the active handheld instrument is deflected as needed via visual servoing in order to correct the error between the aiming beam and a specified target, regardless of any erroneous handle motion by the surgeon. A constant distance of the laser probe from the retinal surface is maintained in order to yield consistent size of burns and ensure safety during operation. Real-time tracking of anatomical features enables compensation for any movement of the eye. A graphical overlay system within operating microscope provides the surgeon with guidance cues for automated operation. Two retinal surgeons performed automated and manual trials in an artificial model of the eye, with each trial repeated three times. For the automated trials, various targeting thresholds (50-200 μm) were used to automatically trigger laser firing. In manual operation, fixed repetition rates were used, with frequencies of 1.0-2.5 Hz. The power of the 532 nm laser was set at 3.0 W with a duration of 20 ms. After completion of each trial, the speed of operation and placement error of burns were measured. The performance of the automated laser photocoagulation was compared with manual operation, using interpolated data for equivalent firing rates from 1.0 to 1.75 Hz.
RESULTS: In automated trials, average error increased from 45 ± 27 to 60 ± 37 μm as the targeting threshold varied from 50 to 200 μm, while average firing rate significantly increased from 0.69 to 1.71 Hz. The average error in the manual trials increased from 102 ± 67 to 174 ± 98 μm as firing rate increased from 1.0 to 2.5 Hz. Compared to the manual trials, the average error in the automated trials was reduced by 53.0-56.4%, resulting in statistically significant differences (P ≤ 10(-20) ) for all equivalent frequencies (1.0-1.75 Hz). The depth of the laser tip in the automated trials was consistently maintained within 18 ± 2 μm root-mean-square (RMS) of its initial position, whereas it significantly varied in the manual trials, yielding an error of 296 ± 30 μm RMS. At high firing rates in manual trials, such as at 2.5 Hz, laser photocoagulation is marginally attained, yielding failed burns of 30% over the entire pattern, whereas no failed burns are found in automated trials. Relatively regular burn sizes are attained in the automated trials by the depth servoing of the laser tip, while burn sizes in the manual trials vary considerably. Automated avoidance of blood vessels was also successfully demonstrated, utilizing the retina-tracking feature to identify avoidance zones.
CONCLUSION: Automated intraocular laser surgery can improve the accuracy of photocoagulation while ensuring safety during operation. This paper provides an initial demonstration of the technique under reasonably realistic laboratory conditions; development of a clinically applicable system requires further work.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  micromanipulation; retinal photocoagulation; robotics; visual servoing

Mesh:

Year:  2015        PMID: 26287813      PMCID: PMC4889221          DOI: 10.1002/lsm.22383

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  27 in total

1.  Automatic trajectory planning for deep brain stimulation: a feasibility study.

Authors:  Ellen J L Brunenberg; Anna Vilanova; Veerle Visser-Vandewalle; Yasin Temel; Linda Ackermans; Bram Platel; Bart M ter Haar Romeny
Journal:  Med Image Comput Comput Assist Interv       Date:  2007

2.  An automated laser system for eye surgery.

Authors:  M S Markow; Y Yang; A J Welch; H G Rylander; W S Weinberg
Journal:  IEEE Eng Med Biol Mag       Date:  1989

3.  Hybrid approach to retinal tracking and laser aiming for photocoagulation.

Authors:  C H Wright; R D Ferguson; H G Rylander Iii; A J Welch; S F Barrett
Journal:  J Biomed Opt       Date:  1997-04       Impact factor: 3.170

4.  Comparison of conventional pattern and novel navigated panretinal photocoagulation in proliferative diabetic retinopathy.

Authors:  Jay Chhablani; Annie Mathai; Padmaja Rani; Vishali Gupta; J Fernando Arevalo; Igor Kozak
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-05-01       Impact factor: 4.799

5.  Toward Automated Intraocular Laser Surgery Using a Handheld Micromanipulator.

Authors:  Sungwook Yang; Robert A MacLachlan; Cameron N Riviere
Journal:  Rep U S       Date:  2014-09

6.  Retinal laser photocoagulation: benefits and risks.

Authors:  R N Frank
Journal:  Vision Res       Date:  1980       Impact factor: 1.886

7.  High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing.

Authors:  Robert A Maclachlan; Cameron N Riviere
Journal:  IEEE Trans Instrum Meas       Date:  2009-06-01       Impact factor: 4.016

Review 8.  Current therapy of diabetic retinopathy: laser and vitreoretinal surgery.

Authors:  S R Wilkes
Journal:  J Natl Med Assoc       Date:  1993-11       Impact factor: 1.798

Review 9.  Efficacy and safety of intravitreal therapy in macular edema due to branch and central retinal vein occlusion: a systematic review.

Authors:  Amelie Pielen; Nicolas Feltgen; Christin Isserstedt; Josep Callizo; Bernd Junker; Christine Schmucker
Journal:  PLoS One       Date:  2013-10-25       Impact factor: 3.240

10.  Initial experience with the Pascal photocoagulator: a pilot study of 75 procedures.

Authors:  C Sanghvi; R McLauchlan; C Delgado; L Young; S J Charles; G Marcellino; P E Stanga
Journal:  Br J Ophthalmol       Date:  2008-06-27       Impact factor: 4.638

View more
  5 in total

1.  EyeSLAM: Real-time simultaneous localization and mapping of retinal vessels during intraocular microsurgery.

Authors:  Daniel Braun; Sungwook Yang; Joseph N Martel; Cameron N Riviere; Brian C Becker
Journal:  Int J Med Robot       Date:  2017-07-18       Impact factor: 2.547

2.  Techniques for robot-aided intraocular surgery using monocular vision.

Authors:  Sungwook Yang; Joseph N Martel; Louis A Lobes; Cameron N Riviere
Journal:  Int J Rob Res       Date:  2018-07-13       Impact factor: 4.703

Review 3.  Robotic Vitreoretinal Surgery.

Authors:  Roomasa Channa; Iulian Iordachita; James T Handa
Journal:  Retina       Date:  2017-07       Impact factor: 4.256

4.  Electromagnetic Tracker for Active Handheld Robotic Systems.

Authors:  Robert A MacLachlan; Nicholas Parody; Shohin Mukherjee; Ralph Hollis; Cameron N Riviere
Journal:  Proc IEEE Sens       Date:  2017-01-09

Review 5.  State of the art of robotic surgery related to vision: brain and eye applications of newly available devices.

Authors:  Raffaele Nuzzi; Luca Brusasco
Journal:  Eye Brain       Date:  2018-02-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.