Maríafe Laguna1,2, Miguel Holgado3,4, Ana L Hernandez5, Beatriz Santamaría6,7, Alvaro Lavín8,9, Javier Soria10, Tatiana Suarez11, Carlota Bardina12, Mónica Jara13, Francisco J Sanza14,15, Rafael Casquel16,17.
Abstract
The specificity and affinity of antibody-antigen interactions is a fundamental way to achieve reliable biosensing responses. Different proteins involved with dry eye dysfunction: ANXA1, ANXA11, CST4, PRDX5, PLAA and S100A6; were validated as biomarkers. In this work several antibodies were tested for ANXA1, ANXA11 and PRDX5 to select the best candidates for each biomarker. The results were obtained by using Biophotonic Sensing Cells (BICELLs) as an efficient methodology for label-free biosensing and compared with the Enzyme-Linked Immuno Sorbent Assay (ELISA) technique.Entities:
Keywords: biosensors; dry eye biomarkers; label-free immunoassay; photonic sensing cells BICELLs
Mesh:
Substances:
Year: 2015 PMID: 26287192 PMCID: PMC4570398 DOI: 10.3390/s150819819
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Antibodies selected from each fusion.
| Protein | Antibody Selected |
|---|---|
| ANXA 1 | P4D1 |
| P6D7 | |
| P10B12 | |
| ANXA11 | P1B11 |
| P3F9 | |
| P4D9 | |
| PRDX5 | P3G1 |
| P5H6 | |
| P9F4 |
Figure 1(a) Optical setup for measurements and biochemical diagram of the immunoassay; (b) optical response for the BICELLs; (c) Bicells used in the immunoassay.
Figure 2Calibration curves for selected monoclonal antibodies. The absorbance measurements are plotted against the protein concentration ranging from 3.125 ng·mL−1 to 200 ng·mL−1: (a) ANXA1; (b) ANXA11; (c) PRDX5.
Figure 3Dip shift against antibody concentration for (a) ANXA1; (b) ANXA11; (c) PRDX5.
Figure 4Equilibrium dissociation constant (KD) measurements obtained using the Elisa technique and the Optical Label-free technique.