Literature DB >> 26286382

Advances in photoplethysmography: beyond arterial oxygen saturation.

Karsten Bartels1, Robert H Thiele2.   

Abstract

PURPOSE: Photoplethysmography permits continuous measurement of heart rate and peripheral oxygen saturation and has been widely used to inform clinical decisions. Recently, a myriad of noninvasive hemodynamic monitoring devices using this same technology have been increasingly available. This narrative review aims to summarize the principles that form the basis for the function of these devices as well as to comment on trials evaluating their accuracy and clinical application. PRINCIPAL
FINDINGS: Advanced monitoring devices extend photoplethysmography technology beyond measuring oxygen concentration and heart rate. Quantification of respiratory variation of the photoplethysmographic waveform reflects respiratory variation of the arterial pressure waveform and can be used to gauge volume responsiveness. Both the volume-clamp and physiocal techniques are extensions of conventional photoplethysmography and permit continuous measurement of finger arterial blood pressure. Finger arterial pressure waveforms can subsequently inform estimations of cardiac output.
CONCLUSIONS: Although respiratory variations of the plethysmographic waveform correlate only modestly with the arterial blood pressure waveform, fluid responsiveness can be relatively consistently assessed using both approaches. Continuous blood pressure measurements obtained using the volume-clamp technique may be as accurate as conventional brachial noninvasive blood pressure measurements. Most importantly, clinical comparative effectiveness studies are still needed in order to determine if these technologies can be translated into improvement of relevant patient outcomes.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26286382     DOI: 10.1007/s12630-015-0458-0

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  4 in total

1.  Heated humidified high-flow nasal cannula oxygen after thoracic surgery - A randomized prospective clinical pilot trial.

Authors:  Jason Brainard; Benjamin K Scott; Breandan L Sullivan; Ana Fernandez-Bustamante; Jerome R Piccoli; Morris G Gebbink; Karsten Bartels
Journal:  J Crit Care       Date:  2017-04-19       Impact factor: 3.425

2.  Digital health care and arrhythmia: a case of WPW syndrome in South Korea, 2020.

Authors:  Eunchan Mun; Jihee Hong; Sunggu Kwon; Sung Ho Lee; Wonsool Kim; Changhwan Lee
Journal:  Ann Occup Environ Med       Date:  2021-03-24

3.  Design of liver functional reserve monitor based on three-wavelength from red light to IR.

Authors:  Fuli Ye; Huimiao Zhan; Guilian Shi
Journal:  Technol Health Care       Date:  2018       Impact factor: 1.285

4.  Using pulse oximetry waveforms to detect coarctation of the aorta.

Authors:  Matthew W Sorensen; Ismail Sadiq; Gari D Clifford; Kevin O Maher; Matthew E Oster
Journal:  Biomed Eng Online       Date:  2020-05-14       Impact factor: 2.819

  4 in total