Literature DB >> 26282486

Fast determination of underivatized gentamicin C components and impurities by LC-MS using a porous graphitic carbon stationary phase.

Manuela Rodriquez1, Daniel S Cretoso1, Maria Anna Euterpio1, Paola Russo1, Carlo Crescenzi2, Rita P Aquino1.   

Abstract

Gentamicin C antibiotics are important because they are active against many multidrug-resistant Gram-negative bacilli. Unfortunately, their clinical usefulness is limited by their toxicity. Because of the difficulty involved in separating its different components, the US and European pharmacopeias both specify that the composition of gentamicin C should be determined by liquid chromatography with pulsed electrochemical detection. Here, we assess the usefulness of a porous graphitic carbon (PGC) HPLC column for separating the components of gentamicin C, and report chromatographic conditions that enable its direct characterization by PGC chromatography directly coupled to electrospray mass spectrometry. Native major components of gentamicin and impurities in commercial formulations were retained and separated on the PGC column without any need for derivatization, using mobile phases basified with ammonium hydroxide. When coupled with detection by conventional electrospray ion trap mass spectrometry (ESI-IT-MS), several previously reported impurities were detected easily, including the most polar gentamicin impurity, garamine. When operating in full-scan mode, it was possible to identify and quantitate gentamicin-related compounds using injected samples of only a few picograms. Under the described conditions, all analytes were eluted in less than 10 min and the LC-MS analyses exhibited excellent stability and linearity. The method's effectiveness was evaluated by analyzing commercial gentamicin batches and in-house formulations. When the PGC chromatographic system was coupled to an evaporative light-scattering detector, detection limits of 40-70 ng were achieved for various major gentamicin components. The chromatographic method was applied on a semi-preparative scale to purify the five major components.

Entities:  

Keywords:  ESI-MS; Evaporative light scattering detector (ELSD); Gentamicin; Gentamicin impurities; HPLC-MS; Porous graphitic carbon (PGC)

Mesh:

Substances:

Year:  2015        PMID: 26282486     DOI: 10.1007/s00216-015-8933-6

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Engineering the methyltransferase through inactivation of the genK and genL leads to a significant increase of gentamicin C1a production in an industrial strain of Micromonospora echinospora 49-92S.

Authors:  Feng Xu; Xinyu Zhang; Ling Liu; Xiang Ke; Jie Wu; Yuanxin Guo; Xiwei Tian; Ju Chu
Journal:  Bioprocess Biosyst Eng       Date:  2022-08-27       Impact factor: 3.434

2.  Exclusive Production of Gentamicin C1a from Micromonospora purpurea by Metabolic Engineering.

Authors:  Zeng Wei; Xianai Shi; Rong Lian; Weibin Wang; Wenrong Hong; Shaobin Guo
Journal:  Antibiotics (Basel)       Date:  2019-12-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.