Literature DB >> 26277651

Graphene oxide based fluorescence resonance energy transfer and loop-mediated isothermal amplification for white spot syndrome virus detection.

U Waiwijit1, D Phokaratkul2, J Kampeera3, T Lomas1, A Wisitsoraat2, W Kiatpathomchai4, A Tuantranont5.   

Abstract

Graphene oxide (GO) is attractived for biological or medical applications due to its unique electrical, physical, optical and biological properties. In particular, GO can adsorb DNA via π-π stacking or non-covalent interactions, leading to fluorescence quenching phenomenon applicable for bio-molecular detection. In this work, a new method for white spot syndrome virus (WSSV)-DNA detection is developed based on loop-mediated isothermal amplification (LAMP) combined with fluorescence resonance energy transfer (FRET) between GO and fluorescein isothiocyanate-labeled probe (FITC-probe). The fluorescence quenching efficiency of FITC-probe was found to increase with increasing GO concentration and reached 98.7% at a GO concentration of 50 μg/ml. The fluorescence intensity of FITC-probe was recovered after hybridization with WSSV LAMP product with an optimal hybridization time of 10 min and increased accordingly with increasing amount of LAMP products. The detection limit was estimated to be as low as 10 copies of WSSV plasmid DNA or 0.6 fg of the total DNA extracted from shrimp infected with WSSV. In addition, no cross reaction was observed with other common shrimp viral pathogens. Therefore, the GO-FRET-LAMP technique is promising for fast, sensitive and specific detection of DNAs.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fluorescence quenching; Fluorescence resonance energy transfer (FRET); Graphene oxide (GO); Loop-mediated isothermal amplification (LAMP); White spot syndrome virus (WSSV)

Mesh:

Substances:

Year:  2015        PMID: 26277651     DOI: 10.1016/j.jbiotec.2015.08.003

Source DB:  PubMed          Journal:  J Biotechnol        ISSN: 0168-1656            Impact factor:   3.307


  6 in total

1.  Reduced False Positives and Improved Reporting of Loop-Mediated Isothermal Amplification using Quenched Fluorescent Primers.

Authors:  Patrick Hardinge; James A H Murray
Journal:  Sci Rep       Date:  2019-05-14       Impact factor: 4.379

Review 2.  Two-dimensional material-based virus detection.

Authors:  Wenbin Wang; Wei Zhai; Ye Chen; Qiyuan He; Hua Zhang
Journal:  Sci China Chem       Date:  2022-01-05       Impact factor: 10.138

Review 3.  Fluorescent Biosensors for the Detection of Viruses Using Graphene and Two-Dimensional Carbon Nanomaterials.

Authors:  Ahmed M Salama; Ghulam Yasin; Mohammed Zourob; Jun Lu
Journal:  Biosensors (Basel)       Date:  2022-06-27

4.  Rapid On-Site Detection Method for White Spot Syndrome Virus Using Recombinase Polymerase Amplification Combined With Lateral Flow Test Strip Technology.

Authors:  Tianmeng Zhang; Xia Liu; Xiaohan Yang; Feixue Liu; Haitao Yang; Xueqing Li; Huimiao Feng; Xinyu Wu; Ge Jiang; Hui Shen; Jingquan Dong
Journal:  Front Cell Infect Microbiol       Date:  2022-07-15       Impact factor: 6.073

5.  Ultrasensitive, high-throughput, and rapid simultaneous detection of SARS-CoV-2 antigens and IgG/IgM antibodies within 10 min through an immunoassay biochip.

Authors:  Chunhua Wang; Chao Wang; Jiaoyan Qiu; Jianwei Gao; Hong Liu; Yu Zhang; Lin Han
Journal:  Mikrochim Acta       Date:  2021-07-20       Impact factor: 5.833

6.  Electrochemical detection of white spot syndrome virus with a silicone rubber disposable electrode composed of graphene quantum dots and gold nanoparticle-embedded polyaniline nanowires.

Authors:  Kenshin Takemura; Jun Satoh; Jirayu Boonyakida; Sungjo Park; Ankan Dutta Chowdhury; Enoch Y Park
Journal:  J Nanobiotechnology       Date:  2020-10-27       Impact factor: 10.435

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.