Literature DB >> 26277212

Cutaneous microemboli from hydrophilic polymer after endovascular procedures.

Agnieszka K Thompson1, Margot S Peters2, Rokea A El-Azhary1, Lawrence E Gibson2, Michael B Chang1, John R Griffin1, Mark D P Davis1, Marian T McEvoy1, Michael J Camilleri2, Alina G Bridges3.   

Abstract

BACKGROUND: Multiple devices and coatings assist with endovascular insertion of sheaths, catheters, and guide wires. Hydrophilic polymer coatings, a common component of endovascular surgical devices, reportedly cause microvascular obstruction and embolization, with various sequelae in organs and soft tissue.
OBJECTIVE: We sought to describe clinical and histopathologic features of cutaneous manifestations of hydrophilic polymer gel emboli.
METHODS: We evaluated the clinical and histopathologic characteristics of 8 patients with cutaneous complications of hydrophilic polymer gel emboli who presented in May 2013 through February 2015.
RESULTS: Sudden onset of lower extremity livedo racemosa, purpuric patches, or both, occurred hours to days after endovascular procedures involving the aorta. Histopathologic evaluation showed basophilic lamellated material, consistent with hydrophilic polymer gel emboli, within small dermal vessels. LIMITATIONS: This was a retrospective study with small sample size and not controlled for all similar procedures in this population.
CONCLUSION: Hydrophilic polymer gel coatings in endovascular devices can embolize to skin and cause microvascular occlusion, presenting as livedo racemosa, purpura, or both. Given the number of patients observed over a short period, this phenomenon may be underappreciated. Hydrophilic polymer gel emboli should be considered in differential diagnosis of livedo racemosa and purpura after endovascular procedure.
Copyright © 2015 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  catheterization; coating; complications; emboli; endovascular procedure; hydrophilic polymer; livedo racemosa; purpura

Mesh:

Substances:

Year:  2015        PMID: 26277212     DOI: 10.1016/j.jaad.2015.07.014

Source DB:  PubMed          Journal:  J Am Acad Dermatol        ISSN: 0190-9622            Impact factor:   11.527


  4 in total

1.  Hydrophilic Polymer Embolism: An Update for Physicians.

Authors:  Rashi I Mehta; Rupal I Mehta
Journal:  Am J Med       Date:  2017-02-16       Impact factor: 4.965

2.  Late-onset Cutaneous Hydrophilic Polymer Embolism: A Case Occurring Two Years after Endovascular Procedures.

Authors:  Yukino Kase; Ryota Hayashi; Izumi Takei; Osamu Ansai; Takeo Suzuki; Akihiko Yuki; Mitsuhiro Watanabe; Takao Yanagawa; Riichiro Abe
Journal:  Acta Derm Venereol       Date:  2021-07-30       Impact factor: 3.875

3.  Cerebral Granulomatous Inflammation Secondary to Hydrophilic Polymer Embolization Following Thrombectomy.

Authors:  Craig Meiers; Yoftahe Abebe; Neville M Alberto; John Riedinger; Dane A Breker; Michael Manchak; Alexander Drofa; Corey Teigen
Journal:  Am J Case Rep       Date:  2017-05-08

Review 4.  Hydrophilic Polymer Embolism: Implications for Manufacturing, Regulation, and Postmarket Surveillance of Coated Intravascular Medical Devices.

Authors:  Rashi I Mehta; Rupal I Mehta
Journal:  J Patient Saf       Date:  2021-12-01       Impact factor: 2.844

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.