Literature DB >> 2627428

Comparison of several noninvasive methods for estimation of pulmonary artery pressure.

J G Stevenson1.   

Abstract

Noninvasive estimation of pulmonary artery pressure is an important component of cardiac ultrasound studies. A number of methods are available for estimation of pulmonary pressure, each with varying degrees of reported accuracy. To assess feasibility and accuracy, noninvasive pulmonary artery pressure estimates were performed in infants and children at the time of catheterization. Patients were examined prospectively until there were 50 patients, in whom each of six methods for estimation of pulmonary pressure had been accomplished. All patients had tricuspid and pulmonary regurgitation of less than severe degree and no structural, flow, or electrocardiographic abnormality known to compromise the six methods. Systolic pressure was estimated by the Burstin method and also from peak tricuspid regurgitation velocity. Mean pressure was estimated by acceleration time divided by ejection time from waveforms obtained from the right ventricular outflow tract and main pulmonary artery. Diastolic pressure was estimated by systolic time intervals and from end-diastolic pulmonary regurgitation velocity. Noninvasive estimates were compared with simultaneous or nearly simultaneous catheterization measurements. For systolic pressure Burstin estimates were accomplished in 89% with high accuracy (r = 0.97). Tricuspid regurgitation velocities were recorded in 82%, also with high accuracy (r = 0.96). Waveforms for mean pressure estimation were recorded in 98% to 100% of patients. Those from the right ventricular outflow tract corresponded well with catheterization pressures (r = 0.94), whereas those recorded from the main pulmonary artery offered poor prediction of pulmonary pressure (r = 0.63). Systolic time interval measurements were accomplished in only 65% and did not correlate highly with catheterization (r = 0.84). Diastolic pressure estimates based on pulmonary regurgitation velocity were recorded in 98% of subjects with high accuracy (r = 0.96). Each method had advantages and disadvantages. The Burstin method was accurate but technically demanding and is reported to be limited by heart rate and significant right-sided regurgitation. Peak tricuspid velocities proved unexpectedly difficult to record in some patients but when successful, provided excellent prediction of pressure. Recording of waveforms for ratios of acceleration time to ejection time proved easy, but accuracy was high only for outflow tract waveforms. Peculiarities of main pulmonary artery flow may have led to poor accuracy for ratios measured from that site. For diastolic pressure estimation, systolic time interval records were the most difficult to obtain and did not provide useful accuracy. In contrast, pulmonary regurgitation velocities were easily obtained and provided high accuracy results. This is a selected pediatric series, evaluating methods in nearly ideal circumstances.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2627428     DOI: 10.1016/s0894-7317(89)80053-7

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  13 in total

1.  Effects of substitutive therapy on right ventricular systolic and diastolic functions in patients with idiopathic hypogonadotropic hypogonadism.

Authors:  Y T Yaylali; G Fidan Yaylali; F Akin; I Susam; M Bastemir
Journal:  J Endocrinol Invest       Date:  2010-09-02       Impact factor: 4.256

Review 2.  European Society of Intensive Care Medicine. Expert panel: the use of the pulmonary artery catheter.

Authors: 
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

3.  Magnetic resonance imaging guided catheterisation for assessment of pulmonary vascular resistance: in vivo validation and clinical application in patients with pulmonary hypertension.

Authors:  T Kuehne; S Yilmaz; I Schulze-Neick; E Wellnhofer; P Ewert; E Nagel; P Lange
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

4.  Haemodynamic features at presentation in persistent pulmonary hypertension of the newborn and outcome.

Authors:  J R Skinner; S Hunter; E N Hey
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-01       Impact factor: 5.747

5.  Noninvasive assessment of acute cardiopulmonary effects of an oral single dose of sildenafil in patients with idiopathic pulmonary hypertension.

Authors:  Neda Behzadnia; Katayoun Najafizadeh; Babak Sharif-Kashani; Davoud Oulad Dameshghi; Payman Shahabi
Journal:  Heart Vessels       Date:  2010-07-31       Impact factor: 2.037

6.  Haemodynamic effects of altering arterial oxygen saturation in preterm infants with respiratory failure.

Authors:  J R Skinner; S Hunter; C F Poets; D W Milligan; D Southall; E N Hey
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-03       Impact factor: 5.747

7.  How to measure peripheral pulmonary vascular mechanics.

Authors:  Naomi C Chesler; Paola Argiento; Rebecca Vanderpool; Michele D'Alto; Robert Naeije
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

8.  Right heart pressure determination by Doppler in infants with tricuspid regurgitation.

Authors:  J R Skinner; A G Stuart; J O'Sullivan; A Heads; R J Boys; S Hunter
Journal:  Arch Dis Child       Date:  1993-08       Impact factor: 3.791

9.  Clinical utility of echocardiography for the diagnosis and management of pulmonary vascular disease in young children with chronic lung disease.

Authors:  Peter M Mourani; Marci K Sontag; Adel Younoszai; D Dunbar Ivy; Steven H Abman
Journal:  Pediatrics       Date:  2008-02       Impact factor: 7.124

10.  Measurement of tricuspid annular diastolic velocities by Doppler tissue imaging to assess right ventricular function in patients with congenital heart disease.

Authors:  M Watanabe; S Ono; T Tomomasa; Y Okada; T Kobayashi; T Suzuki; A Morikawa
Journal:  Pediatr Cardiol       Date:  2003 Sep-Oct       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.