Literature DB >> 26271092

Transcatheter Valve Implantation in Failed Surgically Inserted Bioprosthesis: Review and Practical Guide to Echocardiographic Imaging in Valve-in-Valve Procedures.

Nadira B Hamid1, Omar K Khalique1, Mark J Monaghan2, Susheel K Kodali1, Danny Dvir3, Vinayak N Bapat4, Tamim M Nazif1, Torsten Vahl1, Isaac George1, Martin B Leon1, Rebecca T Hahn5.   

Abstract

An increased use of bioprosthetic heart valves has stimulated an interest in possible transcatheter options for bioprosthetic valve failure given the high operative risk. The encouraging results of transcatheter aortic valve implantation in high-risk surgical candidates with native disease have led to the development of the transcatheter valve-in-valve (VIV) procedures for failed bioprostheses. VIV procedures are unique in many ways, and there is an increased need for multimodality imaging in a team-based approach. The echocardiographic approach to VIV procedures has not previously been described. In this review, we summarize key echocardiographic requirements for optimal patient selection, procedural guidance, and immediate post-procedural assessment for VIV procedures.
Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  TAVR; biological valve replacement; echocardiography

Mesh:

Year:  2015        PMID: 26271092     DOI: 10.1016/j.jcmg.2015.01.024

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  3 in total

1.  Intentional Percutaneous Laceration of the Anterior Mitral Leaflet to Prevent Outflow Obstruction During Transcatheter Mitral Valve Replacement: First-in-Human Experience.

Authors:  Vasilis C Babaliaros; Adam B Greenbaum; Jaffar M Khan; Toby Rogers; Dee Dee Wang; Marvin H Eng; William W O'Neill; Gaetano Paone; Vinod H Thourani; Stamatios Lerakis; Dennis W Kim; Marcus Y Chen; Robert J Lederman
Journal:  JACC Cardiovasc Interv       Date:  2017-04-24       Impact factor: 11.195

Review 2.  Role of Echocardiography in Transcatheter Valvular Heart Disease Interventions.

Authors:  Omar K Khalique; Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2017-10-27       Impact factor: 2.931

3.  Redo Surgical Mitral Valve Replacement Versus Transcatheter Mitral Valve in Valve From the National Inpatient Sample.

Authors:  Muhammad Zia Khan; Salman Zahid; Muhammad U Khan; Asim Kichloo; Shakeel Jamal; Abdul Mannan Khan Minhas; Waqas Ullah; Yasar Sattar; Sudarshan Balla
Journal:  J Am Heart Assoc       Date:  2021-08-28       Impact factor: 5.501

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.