Literature DB >> 26267497

Correction of the heat loss method for calculating clothing real evaporative resistance.

Faming Wang1, Chengjiao Zhang2, Yehu Lu2.   

Abstract

In the so-called isothermal condition (i.e., Tair [air temperature]=Tmanikin [manikin temperature]=Tr [radiant temperature]), the actual energy used for moisture evaporation detected by most sweating manikins was underestimated due to the uncontrolled fabric 'skin' temperature Tsk,f (i.e., Tsk,f<Tmanikin). Thus, it must be corrected before being used to compute the clothing real evaporative resistance. In this study, correction of the real evaporative heat loss from the wet fabric 'skin'-clothing system was proposed and experimentally validated on a 'Newton' sweating manikin. The real evaporative resistance of five clothing ensembles and the nude fabric 'skin' calculated by the corrected heat loss method was also reported and compared with that by the mass loss method. Results revealed that, depending on the types of tested clothing, different amounts of heat were drawn from the ambient environment. In general, a greater amount of heat was drawn from the ambient environment by the wet fabric 'skin'-clothing system in lower thermal insulation clothing than that in higher insulation clothing. There were no significant differences between clothing real evaporative resistances calculated by the corrected heat loss method and those by the mass loss method. It was therefore concluded that the correction method proposed in this study has been successfully validated.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Heat loss method; Isothermal condition; Mass loss method; Real evaporative resistance; Sweating thermal manikin

Mesh:

Year:  2015        PMID: 26267497     DOI: 10.1016/j.jtherbio.2015.05.004

Source DB:  PubMed          Journal:  J Therm Biol        ISSN: 0306-4565            Impact factor:   2.902


  3 in total

1.  Effect of two sweating simulation methods on clothing evaporative resistance in a so-called isothermal condition.

Authors:  Yehu Lu; Faming Wang; Hui Peng
Journal:  Int J Biometeorol       Date:  2015-11-05       Impact factor: 3.787

2.  Effect of sweating set rate on clothing real evaporative resistance determined on a sweating thermal manikin in a so-called isothermal condition (T manikin = T a = T r).

Authors:  Yehu Lu; Faming Wang; Hui Peng; Wen Shi; Guowen Song
Journal:  Int J Biometeorol       Date:  2015-07-07       Impact factor: 3.787

Review 3.  Measurements of clothing evaporative resistance using a sweating thermal manikin: an overview.

Authors:  Faming Wang
Journal:  Ind Health       Date:  2017-06-01       Impact factor: 2.179

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.