Literature DB >> 26267397

Assessing the Impact of Blood Loss in Cranial Vault Remodeling: A Risk Assessment Model Using the 2012 to 2013 Pediatric National Surgical Quality Improvement Program Data Sets.

Ian Chow1, Chad A Purnell, Arun K Gosain.   

Abstract

BACKGROUND: Most cranial vault remodeling for craniosynostosis is associated with substantial blood loss necessitating transfusion. The transfusion of over 25 ml/kg of red blood cells has long been considered an important safety threshold and has been proposed as a potential marker of health care quality, despite a lack of evidence. The authors sought to ascertain risk factors for transfusion in cranial vault remodeling and to quantify the effect of transfusion volume on postoperative complications.
METHODS: Patients who underwent complex cranial vault remodeling for craniosynostosis were identified from the Pediatric National Surgical Quality Improvement Program database. Multivariate regression models were used to identify independent risk factors for transfusion and to assess its impact on subsequent outcomes.
RESULTS: One thousand fifty-nine patients met inclusion criteria. Seven hundred seventy-seven patients (73.4 percent) required a transfusion and 520 patients (49.1 percent) required a transfusion in excess of 25 ml/kg. Neither transfusion nor transfusion volume in excess of 25 ml/kg had a significant effect on postoperative outcomes. Therefore, the authors sought to determine a more meaningful threshold. The top 20 percent of transfusion volumes were greater than or equal to 45.28 ml/kg. Recursive partitioning generated a threshold of 62.52 ml/kg, which independently predicted a greater number of complications and was associated with higher odds ratios than the quintile method. A threshold of 60 ml/kg was chosen for simplicity and was independently predictive of overall complications, medical complications, and increased length of stay.
CONCLUSIONS: Transfusion is common in complex cranial vault remodeling. Currently described occurrence thresholds do not accurately convey postoperative risk. Transfusion in excess of 60 ml/kg significantly increases risk for complications and length of stay in cranial vault remodeling.

Entities:  

Mesh:

Year:  2015        PMID: 26267397     DOI: 10.1097/PRS.0000000000001783

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  4 in total

1.  Tranexamic Acid Dosing in Craniosynostosis Surgery: A Systematic Review with Meta-analysis.

Authors:  Devon B O'Donnell; Sima Vazquez; Jacob D Greisman; Anaz Uddin; Gillian Graifman; Jose F Dominguez; Elizabeth Zellner; Carrie R Muh
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-10-17

2.  Predictors of transfusion outcomes in pediatric complex cranial vault reconstruction: a multicentre observational study from the Pediatric Craniofacial Collaborative Group.

Authors:  Patrick G Fernandez; Brad M Taicher; Susan M Goobie; Meera Gangadharan; H Mayumi Homi; Jane A Kugler; Rochelle Skitt; Lingyu Cai; Marcia Polansky; Paul A Stricker
Journal:  Can J Anaesth       Date:  2019-02-14       Impact factor: 5.063

3.  A 24-month cost and outcome analysis comparing traditional fronto-orbital advancment and remodeling with endoscopic strip craniectomy and molding helmet in the management of unicoronal craniosynostosis: A retrospective bi-institutional review.

Authors:  B A Jivraj; N Ahmed; K Karia; R Menon; E Robertson; A Sodha; J C R Wormald; J O'hara; O Jeelani; D Dunaway; G James; J Ong
Journal:  JPRAS Open       Date:  2019-02-01

4.  Operative Time as the Predominant Risk Factor for Transfusion Requirements in Nonsyndromic Craniosynostosis Repair.

Authors:  Yehuda Chocron; Alain J Azzi; Rafael Galli; Nayif Alnaif; Jeffrey Atkinson; Roy Dudley; Jean-Pierre Farmer; Mirko S Gilardino
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-01-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.