Literature DB >> 26266894

Comparison between Monte Carlo simulation and measurement with a 3D polymer gel dosimeter for dose distributions in biological samples.

T Furuta1, T Maeyama, K L Ishikawa, N Fukunishi, K Fukasaku, S Takagi, S Noda, R Himeno, S Hayashi.   

Abstract

In this research, we used a 135 MeV/nucleon carbon-ion beam to irradiate a biological sample composed of fresh chicken meat and bones, which was placed in front of a PAGAT gel dosimeter, and compared the measured and simulated transverse-relaxation-rate (R2) distributions in the gel dosimeter. We experimentally measured the three-dimensional R2 distribution, which records the dose induced by particles penetrating the sample, by using magnetic resonance imaging. The obtained R2 distribution reflected the heterogeneity of the biological sample. We also conducted Monte Carlo simulations using the PHITS code by reconstructing the elemental composition of the biological sample from its computed tomography images while taking into account the dependence of the gel response on the linear energy transfer. The simulation reproduced the experimental distal edge structure of the R2 distribution with an accuracy under about 2 mm, which is approximately the same as the voxel size currently used in treatment planning.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26266894     DOI: 10.1088/0031-9155/60/16/6531

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

Review 1.  Medical application of particle and heavy ion transport code system PHITS.

Authors:  Takuya Furuta; Tatsuhiko Sato
Journal:  Radiol Phys Technol       Date:  2021-06-30

2.  Radiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams.

Authors:  Takuya Maeyama; Nobuhisa Fukunishi; Kenichi L Ishikawa; Kazuaki Fukasaku; Shigekazu Fukuda
Journal:  J Radiat Res       Date:  2016-03-10       Impact factor: 2.724

3.  Sensitivity enhancement of DHR123 radio-fluorogenic nanoclay gel dosimeter by incorporating surfactants and halogenides.

Authors:  Anri Mochizuki; Takuya Maeyama; Yusuke Watanabe; Shinya Mizukami
Journal:  RSC Adv       Date:  2020-08-04       Impact factor: 4.036

4.  Correlation analysis between 2D and quasi-3D gamma evaluations for both intensity-modulated radiation therapy and volumetric modulated arc therapy.

Authors:  Jung-In Kim; Chang Heon Choi; Hong-Gyun Wu; Jin Ho Kim; Kyubo Kim; Jong Min Park
Journal:  Oncotarget       Date:  2017-01-17

5.  Whole Three-Dimensional Dosimetry of Carbon Ion Beams with an MRI-Based Nanocomposite Fricke Gel Dosimeter Using Rapid T1 Mapping Method.

Authors:  Shinya Mizukami; Yusuke Watanabe; Takahiro Mizoguchi; Tsutomu Gomi; Hidetake Hara; Hideyuki Takei; Nobuhisa Fukunishi; Kenichi L Ishikawa; Shigekazu Fukuda; Takuya Maeyama
Journal:  Gels       Date:  2021-11-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.