Literature DB >> 26265457

Coronary Stents: The Impact of Technological Advances on Clinical Outcomes.

Marco G Mennuni1, Paolo A Pagnotta1, Giulio G Stefanini2.   

Abstract

Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.

Entities:  

Keywords:  Coronary artery disease; Coronary stents; Drug-eluting stents; Myocardial revascularization; Percutaneous coronary interventions

Mesh:

Year:  2015        PMID: 26265457     DOI: 10.1007/s10439-015-1399-z

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  4 in total

1.  Contemporary drug-eluting stents and companion polymers: durable is not synonymous with harm.

Authors:  Salvatore Cassese; Sebastian Kufner; Adnan Kastrati
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

2.  Unprotected versus protected high-risk percutaneous coronary intervention with the Impella 2.5 in patients with multivessel disease and severely reduced left ventricular function.

Authors:  Tobias Becher; Frederik Eder; Stefan Baumann; Dirk Loßnitzer; Berit Pollmann; Michael Behnes; Martin Borggrefe; Ibrahim Akin
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

3.  The Drug Coated Balloon-Only Strategy for Treatment of de Novo Left Main Coronary Artery Bifurcation Lesion: Stentless Strategy.

Authors:  Hengdao Liu; Yanyan Zhao; Yang Lu; Shilong Zhou; Yubin Zhang; Junwei Zhao; Huilin Yang; Junhui Xing; Ruihan Feng; XiaoFei Xue; Hailong Tao; Ruipeng Song; Heping Gu
Journal:  Clin Appl Thromb Hemost       Date:  2022 Jan-Dec       Impact factor: 3.512

4.  Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patients with acute myocardial infarction.

Authors:  Paweł Gąsior; Marek Gierlotka; Krzysztof Szczurek-Katanski; Marcin Osuch; Magda Roleder; Michal Hawranek; Mariusz Gasior; Wojciech Wojakowski; Lech Polonski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-11-09       Impact factor: 1.426

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.