Early results of MitraClip system implantation by real-time three-dimensional speckle-tracking left ventricle analysis.

Salvatore Scandura1, Fabio Dipasqua, Giuseppe Gargiulo, Davide Capodanno, Anna Caggegi, Carmelo Grasso, Sarah Mangiafico, Anna Maria Pistritto, Sebastiano Immè, Marta Chiarandà, Margherita Ministeri, Giuseppe Ronsivalle, Stefano Cannata, Antonio Andrea Arcidiacono, Piera Capranzano, Corrado Tamburino.   

Abstract

AIMS: To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE).
METHODS: Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume).
RESULTS: In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ± 73.7 ml at baseline vs. 159.8 ± 64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ± 52.0 vs. 100.1 ± 50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ± 11.3% at baseline vs. 39.4 ± 11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ± 2.0 l/min at baseline vs. 4.0 ± 1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ± 25.5 ml at baseline vs. 59.9 ± 20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from -9.8 ± 4.1% at baseline to -11.0 ± 4.4% at follow-up (P = 0.018).
CONCLUSIONS: Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up.

Entities:  

Mesh:

Year:  2016        PMID: 26258717     DOI: 10.2459/JCM.0000000000000284

Source DB:  PubMed          Journal:  J Cardiovasc Med (Hagerstown)        ISSN: 1558-2027            Impact factor:   2.160


  4 in total

Review 1.  Three-dimensional speckle-tracking echocardiography: benefits and limitations of integrating myocardial mechanics with three-dimensional imaging.

Authors:  Denisa Muraru; Alice Niero; Hugo Rodriguez-Zanella; Diana Cherata; Luigi Badano
Journal:  Cardiovasc Diagn Ther       Date:  2018-02

Review 2.  A review of current trends in three-dimensional analysis of left ventricular myocardial strain.

Authors:  Yosuke Nabeshima; Yoshihiro Seo; Masaaki Takeuchi
Journal:  Cardiovasc Ultrasound       Date:  2020-06-26       Impact factor: 2.062

Review 3.  Speckle tracking echocardiography in primary mitral regurgitation: should we reconsider the time for intervention?

Authors:  Maria Concetta Pastore; Giulia Elena Mandoli; Aleksander Dokollari; Gianluigi Bisleri; Flavio D'Ascenzi; Ciro Santoro; Marcelo Haertel Miglioranza; Marta Focardi; Luna Cavigli; Giuseppe Patti; Serafina Valente; Sergio Mondillo; Matteo Cameli
Journal:  Heart Fail Rev       Date:  2021-04-07       Impact factor: 4.654

4.  Association of left ventricular global area strain derived from resting 3D speckle-tracking echocardiography and exercise capacity in individuals undergoing treadmill exercise test.

Authors:  Tsang-Wei Chang; Han-Chung Hsu; Wei-Chuan Tsai
Journal:  Int J Med Sci       Date:  2022-09-11       Impact factor: 3.642

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.