| Literature DB >> 26258115 |
Abstract
Velopharyngeal dysfunction in cleft palate patients following the primary palate repair may result in nasal air emission, hypernasality, articulation disorder and poor intelligibility of speech. Among conservative treatment methods, speech aid prosthesis combined with speech therapy is widely used method. However because of its long time of treatment more than a year and low predictability, some clinicians prefer a surgical intervention. Thus, the purpose of this report was to increase an attention on the effectiveness of speech aid prosthesis by introducing a case that was successfully treated. In this clinical report, speech bulb reduction program with intensive speech therapy was applied for a patient with velopharyngeal dysfunction and it was rapidly treated by 5months which was unusually short period for speech aid therapy. Furthermore, advantages of pre-operative speech aid therapy were discussed.Entities:
Keywords: Speech aid prosthesis; Speech bulb; Speech therapy; VPD; VPI; Velopharyngeal dysfunction; Velopharyngeal incompetence; Velopharyngeal insufficiency
Year: 2015 PMID: 26258115 PMCID: PMC4525334 DOI: 10.1186/s40902-015-0022-4
Source DB: PubMed Journal: Maxillofac Plast Reconstr Surg ISSN: 2288-8101
Results of nasometric assessment before and after intervention
| Nasalance score (%) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Vowels | /a/ | /i/ | /e/ | /o/ | /u/ | /ja/ | /je/ | /wi/ |
| Mean (%) | 8.6 | 22.3 | 8.7 | 8.4 | 10.0 | 8.5 | 8.6 | 20.5 |
| Before Intervention | 37.5 | 78.4 | 49.5 | 42.3 | 53.4 | 35.5 | 53.9 | 39.2 |
| After Intervention | 4.1 | 12.7 | 3.3 | 2.7 | 4.3 | 3.7 | 5.7 | 9.5 |
Fig. 1Changes of nasalance score for vowels before and after placement of the speech aids
Degree of nasalance and suggested treatment options for VPD (Shin’s criteria)
| Nasalance | Recommended options of treatment | |
|---|---|---|
| Below 20 % | No nasality | |
| 20 ~ 35 % | Mild nasality | Speech therapy |
| 35 ~ 45 % | Moderate nasality (marginal VPD) | Speech aid appliance with speech therapy |
| 45 ~ 60 % | High nasality | Surgery or speech aid |
| Over 60 % | Severe nasality (VPD) | Surgery |