Methods of estimating liner compression.

S Leonardi1, J F Penry2, F M Tangorra1, P D Thompson3, D J Reinemann3.   

Abstract

The aim of this study was to compare 2 methods of measuring overpressure (OP) using a new test device designed to make OP measurements more quickly and accurately. Overpressure was measured with no pulsation (OP np) and with limited pulsation (OP lp) repeatedly on the same cow during a single milking. Each of the 6 liners (3 round liners and 3 triangular liners) used in this study were tested on the same 6 experimental cows. Both OP np and OP lp were measured on all 4 teats of each experimental cow twice for each liner. The order of OP np and OP lp alternated sequentially for each cow test. The OP results for the 6 liners were also compared with liner compression estimated on the same liners with a novel artificial teat sensor (ATS). The OP lp method showed small but significantly higher values than the OP np method (13.9 vs. 13.4 kPa). The OP lp method is recommended as the preferred method as it more closely approximates normal milking condition. Overpressure values decreased significantly between the first and the following measurements, (from 15.0 to 12.4 kPa). We recommend performing the OP test at a consistent time, 1 min after attaching the teatcup to a well-stimulated teat, to reduce the variability produced by OP changing during the peak flow period. The new test device had several advantages over previously published methods of measuring OP. A high correlation between OP and liner compression estimated by the ATS was found, but difficulties were noted when using the ATS with triangular liners.
Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  artificial teat sensor; liner compression; overpressure

Mesh:

Year:  2015        PMID: 26254519     DOI: 10.3168/jds.2015-9380

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  3 in total

1.  Milk-flow data collected routinely in an automatic milking system: an alternative to milking-time testing in the management of teat-end condition?

Authors:  Håvard Nørstebø; Amira Rachah; Gunnar Dalen; Odd Rønningen; Anne Cathrine Whist; Olav Reksen
Journal:  Acta Vet Scand       Date:  2018-01-11       Impact factor: 1.695

2.  The Use of a Pressure-Indicating Film to Determine the Effect of Liner Type on the Measured Teat Load Caused by a Collapsing Liner.

Authors:  Susanne Demba; Viktoria Paul; Christian Ammon; Sandra Rose-Meierhöfer
Journal:  Sensors (Basel)       Date:  2017-04-13       Impact factor: 3.576

3.  The Usability of a Pressure-Indicating Film to Measure the Teat Load Caused by a Collapsing Liner.

Authors:  Susanne Demba; Sabrina Elsholz; Christian Ammon; Sandra Rose-Meierhöfer
Journal:  Sensors (Basel)       Date:  2016-09-28       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.