A New Fluorescence Turn-On Probe for Aluminum(III) with High Selectivity and Sensitivity, and its Application to Bioimaging.

Yi Jiang1, Lei-Li Sun1, Guang-Zong Ren1, Xiang Niu1, Wen-Zhou Hu1, Zhi-Qiang Hu1.   

Abstract

The development of novel selective probes with high sensitivity for the detection of Al(3+) is widely considered an important research goal due to the importance of such probes in medicine, living systems and the environment. Here, we describe a new fluorescent probe, N'-(4-diethylamino-2-hydroxybenzylidene)-2-hydroxybenzohydrazide (1), for Al(3+). Probe 1 was evaluated in a solution of acetonitrile/water (1:1 v/v). Compared with previously reported probes for Al(3+), probe 1 can be synthesized easily and in high yield. A Job plot confirmed that probe 1 is able to complex Al(3+) in a 1:1 ratio, and the binding constant was determined to be 4.25×10(8) m(-1). Moreover, the detection limit was as low as 6.7×10(-9) m, suggesting that probe 1 has a high sensitivity. Common coexistent metal ions, such as K(+), Co(2+), Ca(2+), Ba(2+), Ni(2+), Pb(2+), Hg(2+), Ce(2+), Zn(2+), Cd(2+), Fe(3+), showed little or no interference in the detection of Al(3+) in solution, demonstrating the high selectivity of the probe. Finally, the ability of probe 1 to act as a fluorescent probe for Al(3+) in living systems was evaluated in Gram-negative bacteria, Escherichia coli, and confocal laser scanning microscopy confirmed its utility. The results of this study suggest that 1 has appropriate properties to be developed for application as a fluorescent probe of Al(3+) for use in biological studies.

Entities:  

Keywords:  aluminum(III); bioimaging; fluorescent probes; selectivity; sensitivity

Year:  2015        PMID: 26247000      PMCID: PMC4522188          DOI: 10.1002/open.201402169

Source DB:  PubMed          Journal:  ChemistryOpen        ISSN: 2191-1363            Impact factor:   2.911


Introduction

It is widely considered meaningful to develop new selective and sensitive chemosensors for the detection of metal ions due to their important roles in medicine, living systems, and the environment.1,2 Among metals, aluminum is the third most prevalent element (8.3 % by weight) in the earths crust. Acid rain can leach aluminum from soil and increases the concentration of free Al3+ in surface water, which is detrimental to growing plants.3–5 Consequently, about 40 % of the worlds acidic soil is caused by aluminum toxicity.6–8 Furthermore, people are widely exposed to aluminum because of its widespread use in food additives, aluminum-based pharmaceuticals, and so on.9,10 The toxicity of aluminum leads to damage to the central nervous system (CNS), which is suspected to be involved in neurodegenerative diseases such as Alzheimers and Parkinsons diseases.11,12 The World Health Organization (WHO) reported that the average daily human intake of aluminum is approximately 3–10 mg.13,14 However, compared with other metal ions, the detection of Al3+ has always been a great challenge because of its poor coordination ability, strong hydration ability, and the lack of spectroscopic characteristics.15–17 To date, many fluorescent probes have been developed to detect Al3+.18–32 To the best of our knowledge, although many Schiff base derivatives bearing a fluorescent moiety have been used to detect various metal ions,33 Schiff base-type Al3+ sensors used for bioimaging remain rare.20,28,30,32d Here, we report a previously identified Schiff base derivative (1)34 (Scheme 1) as the fluorescent turn-on probe for detection of Al3+. Compared with the reported probes for Al3+, probe 1 can be synthesized easily in high yields. Common coexistent metal ions showed little or no interference in the detection of Al3+, demonstrating the high selectivity of probe 1. More importantly, the detect limit of probe 1 towards Al3+ is extremely low (6.7×10−9 m), suggesting its high sensitivity. These advantages are helpful to its further application in areas such as bioimaging.
Scheme 1

Synthesis of chemosensor 1. Reagents and conditions: a) Piperidine, EtOH, 81 %.[34]

Synthesis of chemosensor 1. Reagents and conditions: a) Piperidine, EtOH, 81 %.[34]

Results and Discussion

Probe 1 was soluble in acetonitrile and slightly soluble in water. Therefore, the selectivity of 1 to various metal ions, namely K+, Co2+, Ca2+, Ba2+, Ni2+, Pb2+, Hg2+, Ce2+, Zn2+, Cd2+, Fe3+, Al3+ (5.0 equiv), was examined in an acetonitrile/water solution (1:1 v/v). As shown in Figure 1, probe 1 alone displays very weak fluorescence when excited at 400 nm. The addition of 5.0 equiv of K+, Co2+, Ca2+, Ba2+, Ni2+, Pb2+, Hg2+, Ce2+, Zn2+, Cd2+, or Fe3+ had no obvious effect on the fluorescence of probe 1. However, upon addition of 5.0 equiv of Al3+, the emission intensity was largely enhanced at 467 nm.
Figure 1

Fluorescence responses of 1 (5 μm, λex=400 nm) upon addition of 5.0 equiv of various metal ions in CH3CN/H2O (1:1 v/v).

Fluorescence responses of 1 (5 μm, λex=400 nm) upon addition of 5.0 equiv of various metal ions in CH3CN/H2O (1:1 v/v). Achieving a highly selective response to the targeted analyte over a complex background of potentially competitive species is an important requirement for a chemosensor. Thus, the competitive experiments were then carried out by addition of 10.0 equiv of Al3+ to the solutions of 1 in the presence of 100.0 equiv of other metal ions, in order to validate the high selectivity of 1 as a chemosensor for the detection of Al3+. As shown in Figure 2, there is nearly no interference for the detection of Al3+ in the presence of other metal ions. These results demonstrate that 1 displays a high selectivity for Al3+ in the acetonitrile/water solution (1:1 v/v).
Figure 2

Fluorescence responses of 1 (5 μm) at 467 nm, in the absence and presence of different metal ions (5.0 equiv). The measured fluorescence intensity (I–I0) of probe 1 in the presence of both the indicated metal ion (black bar) and the indicated metal ion plus 100 equiv Al3+ (red bar).

Fluorescence responses of 1 (5 μm) at 467 nm, in the absence and presence of different metal ions (5.0 equiv). The measured fluorescence intensity (I–I0) of probe 1 in the presence of both the indicated metal ion (black bar) and the indicated metal ion plus 100 equiv Al3+ (red bar). The UV-vis absorption of 1 in acetonitrile/water (1:1 v/v) was investigated by spectrophotometric titration. As shown in Figure 3 a, in the presence of Al3+ (5.0 equiv), a new absorbance band appears at approximately 350 nm. However, no obvious changes in the UV-vis absorption spectra of 1 were observed in the presence of other metal ions. Furthermore, the absorbance peak at ∼350 nm increased gradually upon gradual addition of Al3+ to the solution of 1 (Figure 3 b).
Figure 3

a) UV-vis absorption spectra of 1 upon addition of various metal ions (5.0 equiv) in CH3CN/H2O (1:1 v/v); b) Absorption titration spectra of 1 (5 μm) in CH3CN/H2O (1:1 v/v) in the presence of increasing concentrations of Al3+ (0–8 equiv).

a) UV-vis absorption spectra of 1 upon addition of various metal ions (5.0 equiv) in CH3CN/H2O (1:1 v/v); b) Absorption titration spectra of 1 (5 μm) in CH3CN/H2O (1:1 v/v) in the presence of increasing concentrations of Al3+ (0–8 equiv). Titration of a 5 μm solution of 1 in acetonitrile/water (1:1 v/v) by gradual addition of Al3+ was carried out. Upon incremental addition of Al3+, the fluorescence intensity at 467 nm of 1 in solution increased gradually (Figure 4 a). Figure 4 b shows relative intensity (I/I0) versus the concentration of Al3+ in the low concentration region up to 6.7×10−9 m, suggesting that probe 1 could act as a chemosensor for the detection of Al3+ with extraordinarily high sensitivity compared with other chemosensors.18–32
Figure 4

a) Fluorescence titration of 1 (5 μm) with Al3+ in CH3CN/H2O (1:1 v/v) with increasing concentrations of Al3+ (λex=400 nm); b) fluorescence of 1 (5 μm) at 467 nm as a function of Al3+ concentration (0–8×10−9 m).

a) Fluorescence titration of 1 (5 μm) with Al3+ in CH3CN/H2O (1:1 v/v) with increasing concentrations of Al3+ (λex=400 nm); b) fluorescence of 1 (5 μm) at 467 nm as a function of Al3+ concentration (0–8×10−9 m). To investigate the binding stoichiometry of the 1–Al3+ complex, a Jobs plot based on fluorescence data was generated (Figure 5), showing a maximum emission intensity when the molecular fraction of Al3+ was approximately a half, suggesting that probe 1 complexes with Al3+ in a 1:1 ratio. According to the linear Benesi–Hildebrand expression,35 the measured fluorescence intensity 1/(I–I0) at 467 nm showed a linear relationship with [1]/[Al3+]. Using the Benesi–Hildebrand plot (Figure 6), the binding constant of the 1–Al3+ complex was found to be 4.25×108 m−1 (R=0.998).
Figure 5

Jobs plot to determine the stoichiometry of the 1–Al3+ complex (λex=400 nm). Fluorescence at 467 nm was plotted as a function of the molar ratio: [Al3+]/([Al3+]+[1]).

Figure 6

Benesi–Hildebrand plot (λem=467 nm) of fluorescence intensity 1/(I–I0) of 1 as a function of 1/[Al3+].

Jobs plot to determine the stoichiometry of the 1–Al3+ complex (λex=400 nm). Fluorescence at 467 nm was plotted as a function of the molar ratio: [Al3+]/([Al3+]+[1]). Benesi–Hildebrand plot (λem=467 nm) of fluorescence intensity 1/(I–I0) of 1 as a function of 1/[Al3+]. The pH influence on the sensitivity of probe 1 for Al3+ was also examined under various pH conditions (Figure 7). As expected, 1 was found to be weakly fluorescent in acetonitrile/water (1:1 v/v) and showed a significantly positive response (strong fluorescence) between pH 6.8 and 7.4 upon the addition of Al3+. The biologically relevant pH range is 6.0–7.6,20 thus, fluorescent probe 1 could be used to detect intracellular Al3+ without being affected by the physiological pH.
Figure 7

Effect of pH on the fluorescence intensity of chemosensor 1 (5 μm) (▪) at 467 nm, and 1 upon addition of 10 equiv Al3+ in CH3CN/H2O (1:1 v/v) (•).

Effect of pH on the fluorescence intensity of chemosensor 1 (5 μm) (▪) at 467 nm, and 1 upon addition of 10 equiv Al3+ in CH3CN/H2O (1:1 v/v) (•). The ability of biosensing molecules to selectively monitor guest species in living systems recently attracted much attention due to their importance in biological applications.36,37 Therefore, we evaluated fluorescent probe 1 against Escherichia coli, a Gram-negative bacteria, to demonstrate its potential application in biological systems. E. coli cells were incubated with 1 (10 μm) for one hour at 37 °C, after which time no obvious fluorescence could be detected (Figure 8 a). In contrast, a strong fluorescent image was observed in E. coli cells incubated with both 1 and Al3+ (Figure 8 b). The bright field transmission image of the E. coli cells (Figure 8 c) was exactly consistent with the fluorescence image in Figure 8 b. These results suggested that 1 is cell-membrane permeable and could be used for detecting Al3+ within living systems.
Figure 8

Confocal fluorescence images of E. coli. a) Bacteria after incubation with probe 1 (10.0 μm) for 1 h; b) bacteria after incubation with AlCl3 (200 μm) in DMSO/H2O (1:1 v/v) for 10 min, then with 1 (10.0 μm) for 1 h; c) bright field image of E. coli. The images were taken at 2000× magnification, and the size of each square presented is 25 μm×25 μm.

Confocal fluorescence images of E. coli. a) Bacteria after incubation with probe 1 (10.0 μm) for 1 h; b) bacteria after incubation with AlCl3 (200 μm) in DMSO/H2O (1:1 v/v) for 10 min, then with 1 (10.0 μm) for 1 h; c) bright field image of E. coli. The images were taken at 2000× magnification, and the size of each square presented is 25 μm×25 μm.

Conclusion

We have synthesized a probe (1) that could selectively detect Al3+ with high sensitivity. Upon the formation of the 1–Al3+ complex, obvious detectable changes in absorbance and fluorescence were observed. The recognition behavior of probe 1 towards Al3+ was carefully investigated by experimental studies to give the binding stoichiometry and binding constant, and the level of detection limit, which is extremely low. More importantly, confocal laser scanning microscopy showed the application of fluorescent probe 1 as an imaging reagent for detection of Al3+ in E. coli, demonstrating its value in practical applications in biological systems.

Experimental Section

General materials and methods: All materials for synthesis of probe 1 were obtained in analytical grade from Alfa Aesar, A Johnson Matthey Company, and used without further purification. All solvents used in spectroscopic experiments were spectroscopic grade. Distilled, deionized water was used throughout the experiments. NMR spectra were recorded on a Bruker DRX spectrometer operating at 500 MHz or 125 MHz (Bruker Scientific Technology Co. Ltd, Beijing, P. R. China). Chemical shifts (δ) are reported in parts per million (ppm) relative to an internal standard (TMS). A Hitachi F-4500 spectrofluorometer (Hitachi High Technologies Co. Ltd, Shanghai, P. R. China) was used for fluorescence measurements. Absorption spectra were recorded with a Techcomp UV-8500 spectrophotometer (Shanghai Techcomp Scientific Instrument Co. Ltd, Shanghai, P. R. China). Synthesis of­ ′-(4-diethylamino-2-hydroxybenzylidene)-2-hydroxybenzohydrazide (1):34 A solution of 2-hydroxybenzohydrazide (3) (1.52 g, 10 mmol), 4-(diethylamino)salicylaldehyde (2) (1.93 g, 10 mmol), and piperidine (0.50 mL) in EtOH (25 mL) was heated at reflux for 4 h. The resulting yellow precipitate was isolated by filtration and then washed with EtOH to give the crude product. Purification by column chromatography (hexane/EtOAc, 2:1→1:1) gave the title compound as a pale yellow solid (2.77 g, 81 % yield): 1H NMR (500 MHz, [D6]DMSO): δ=8.48 (s, 1 H), 7.87 (d, J=6.5 Hz, 1 H), 7.44–7.42 (m, 1 H), 7.29 (d, J=8.5 Hz, 1 H), 6.97–6.93 (m, 2 H), 6.38 (d, J=8.5 Hz, 1 H), 6.24 (s, 1 H), 3.38 (q, J=7.0 Hz, 4 H), 1.09 ppm (t, J=7.0 Hz, 6 H); 13C NMR (125 MHz, [D6]DMSO): δ=165.0, 159.8, 159.6, 150.2, 134.5, 132.1, 129.2, 119.5, 117.8, 116.0, 48.5, 11.7 ppm; MS (ESI): m/z=327 [M]+. Characterization data are in line with those reported in Ref. 34. Fluorometric and UV-vis titrations: Solutions (5.0 mm) of K+, Co2+, Ca2+, Ba2+, Ni2+, Pb2+, Hg2+, Ce2+, Zn2+, Cd2+, Fe3+, and Al3+ in CH3CN/H2O (1:1 v/v) were prepared from the chloride or nitrate salt. A solution (5 μm) of probe 1 in CH3CN/H2O (1:1 v/v) was also prepared for titration purposes. Titrations were carried out at room temperature. During titration, 5.0 mm metal ion solution was added using a micro-injector to a solution of 1 (5 μm, 3 mL); the volume of metal ion solution could be ignored compared to that of 1. Measurements were taken after 2 h. Excitation and emission slits of 5.0 nm were used for all the measurements of fluorescence. Preparation of­ ­ cells: E. coli was obtained from the Qingdao Institute of Bioenergy and Bioprocess Technology (QIBEBT) of the Chinese Academy of Sciences (CAS). Nutrient broth and trypticase soy broth were obtained from Aladdin Reagent Company (Shanghai, China). After incubation at 37 °C for 24 h, stock cultures were maintained on trypticase soy agar slants at 4 °C. A loop of bacteria was resuspended in nutrient broth (5 mL) and trypticase soy broth (50 mL) without glucose (1.5 % trypticase, 0.5 % soytone, and 0.5 % NaCl). The culture broth was incubated with shaking for 15–18 h at 37 °C. Bacteria were washed with sterile 0.85 % saline (4–5 mL) and then centrifuged twice (3000 rpm, rt, 30 min) to remove culture medium from the bacterial pellet. Before use, bacteria were resuspended in 0.025 m phosphate buffer (pH 6.8) (4 mL). Confocal fluorescence imaging: Confocal fluorescence imaging was performed on a Leica TCS SP5 laser scanning confocal microscope (Leica Microsystems, Wetzlar, Germany), with a blue diode laser (50 mW, λex=405 nm) and acquisition as xyz at a speed of 400 Hz.
  29 in total

1.  A unique water-tuning dual-channel fluorescence-enhanced sensor for aluminum ions based on a hybrid ligand from a 1,1'-binaphthyl scaffold and an amino acid.

Authors:  Tian-Hua Ma; Ming Dong; Yu-Man Dong; Ya-Wen Wang; Yu Peng
Journal:  Chemistry       Date:  2010-09-10       Impact factor: 5.236

2.  Salicylimine-based fluorescent chemosensor for aluminum ions and application to bioimaging.

Authors:  Soojin Kim; Jin Young Noh; Ka Young Kim; Jin Hoon Kim; Hee Kyung Kang; Seong-Won Nam; So Hyun Kim; Sungsu Park; Cheal Kim; Jinheung Kim
Journal:  Inorg Chem       Date:  2012-03-02       Impact factor: 5.165

3.  Highly selective ion probe for Al3+ based on Au(I)···Au(I) interactions in a bis-alkynyl calix[4]arene Au(I) isocyanide scaffold.

Authors:  Franky Ka-Wah Hau; Xiaoming He; Wai Han Lam; Vivian Wing-Wah Yam
Journal:  Chem Commun (Camb)       Date:  2011-07-08       Impact factor: 6.222

4.  A new half-condensed Schiff base compound: highly selective and sensitive pH-responsive fluorescent sensor.

Authors:  Uday Chand Saha; Koushik Dhara; Basab Chattopadhyay; Sushil Kumar Mandal; Swastik Mondal; Supriti Sen; Monika Mukherjee; Sander van Smaalen; Pabitra Chattopadhyay
Journal:  Org Lett       Date:  2011-08-09       Impact factor: 6.005

5.  Novel optical/electrochemical selective 1,2,3-triazole ring-appended chemosensor for the Al3+ ion.

Authors:  Sang Hoon Kim; Hong Seok Choi; Joohoon Kim; Suk Joong Lee; Duong Tuan Quang; Jong Seung Kim
Journal:  Org Lett       Date:  2010-02-05       Impact factor: 6.005

Review 6.  Aluminum salts in vaccines--US perspective.

Authors:  Norman W Baylor; William Egan; Paul Richman
Journal:  Vaccine       Date:  2002-05-31       Impact factor: 3.641

7.  Preparation of ethambutol-copper(II) complex and fabrication of PVC based membrane potentiometric sensor for copper.

Authors:  Vinod K Gupta; Rajendra Prasad; Azad Kumar
Journal:  Talanta       Date:  2003-05-28       Impact factor: 6.057

Review 8.  Neurodegenerative diseases and oxidative stress.

Authors:  Kevin J Barnham; Colin L Masters; Ashley I Bush
Journal:  Nat Rev Drug Discov       Date:  2004-03       Impact factor: 84.694

9.  Coumarin-derived Cu(2+)-selective fluorescence sensor: synthesis, mechanisms, and applications in living cells.

Authors:  Hyo Sung Jung; Pil Seung Kwon; Jeong Won Lee; Jae Il Kim; Chang Seop Hong; Jong Wan Kim; Shihai Yan; Jin Yong Lee; Jung Hwa Lee; Taiha Joo; Jong Seung Kim
Journal:  J Am Chem Soc       Date:  2009-02-11       Impact factor: 15.419

10.  A highly selective fluorescent chemosensor for Al(III) ion and fluorescent species formed in the solution.

Authors:  Wei-Hua Ding; Wei Cao; Xiang-Jun Zheng; De-Cai Fang; Wing-Tak Wong; Lin-Pei Jin
Journal:  Inorg Chem       Date:  2013-06-20       Impact factor: 5.165

View more
  1 in total

1.  A Naphthalimide-Based Fluorescence "Off-on-Off" Chemosensor for Relay Detection of Al3+ and ClO.

Authors:  Xue-Jiao Sun; Ting-Ting Liu; Hong Fu; Na-Na Li; Zhi-Yong Xing; Fan Yang
Journal:  Front Chem       Date:  2019-08-02       Impact factor: 5.221

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.