Literature DB >> 26240969

The effects of metal ion PCR inhibitors on results obtained with the Quantifiler(®) Human DNA Quantification Kit.

Laura Gaydosh Combs1, Joseph E Warren2, Vivian Huynh3, Joanna Castaneda4, Teresa D Golden5, Rhonda K Roby6.   

Abstract

Forensic DNA samples may include the presence of PCR inhibitors, even after extraction and purification. Studies have demonstrated that metal ions, co-purified at specific concentrations, inhibit DNA amplifications. Metal ions are endogenous to sample types, such as bone, and can be introduced from environmental sources. In order to examine the effect of metal ions as PCR inhibitors during quantitative real-time PCR, 2800 M DNA was treated with 0.0025-18.750 mM concentrations of aluminum, calcium, copper, iron, nickel, and lead. DNA samples, both untreated and metal-treated, were quantified using the Quantifiler(®) Human DNA Quantification Kit. Quantification cycle (Cq) values for the Quantifiler(®) Human DNA and internal PCR control (IPC) assays were measured and the estimated concentrations of human DNA were obtained. Comparisons were conducted between metal-treated and control DNA samples to determine the accuracy of the quantification estimates and to test the efficacy of the IPC inhibition detection. This kit is most resistant to the presence of calcium as compared to all metals tested; the maximum concentration tested does not affect the amplification of the IPC or quantification of the sample. This kit is most sensitive to the presence of aluminum; concentrations greater than 0.0750 mM negatively affected the quantification, although the IPC assay accurately assessed the presence of PCR inhibition. The Quantifiler(®) Human DNA Quantification Kit accurately quantifies human DNA in the presence of 0.5000 mM copper, iron, nickel, and lead; however, the IPC does not indicate the presence of PCR inhibition at this concentration of these metals. Unexpectedly, estimates of DNA quantity in samples treated with 18.750 mM copper yielded values in excess of the actual concentration of DNA in the samples; fluorescence spectroscopy experiments indicated this increase was not a direct interaction between the copper metal and 6-FAM dye used to label the probe that targets human DNA in the Quantifiler(®) kit. Evidence of inhibition was observed for the human-specific assay at a lower metal concentration than detected by the IPC, for all metals examined except calcium. These results strongly suggest that determination of a "true negative" sample should not be based solely on the failure of the IPC to indicate the presence of a PCR inhibitor and indicate that amplification of all samples should be attempted, regardless of the quantification results.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  6-Carboxyfluorescein; DNA quantification; Fluorescence spectroscopy; Metal ions; PCR inhibition

Mesh:

Substances:

Year:  2015        PMID: 26240969     DOI: 10.1016/j.fsigen.2015.06.013

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  6 in total

1.  Assessment of impact of DNA extraction methods on analysis of human remain samples on massively parallel sequencing success.

Authors:  Xiangpei Zeng; Kyleen Elwick; Carrie Mayes; Maiko Takahashi; Jonathan L King; David Gangitano; Bruce Budowle; Sheree Hughes-Stamm
Journal:  Int J Legal Med       Date:  2018-10-19       Impact factor: 2.686

2.  Non-Contact Temperature Control System Applicable to Polymerase Chain Reaction on a Lab-on-a-Disc.

Authors:  Junguk Ko; Jae-Chern Yoo
Journal:  Sensors (Basel)       Date:  2019-06-09       Impact factor: 3.576

3.  False-positive and false-negative COVID-19 cases: respiratory prevention and management strategies, vaccination, and further perspectives.

Authors:  Dimitra S Mouliou; Konstantinos I Gourgoulianis
Journal:  Expert Rev Respir Med       Date:  2021-04-25       Impact factor: 3.772

4.  Spatiotemporal Regulation of Metal Ions in the Polymerase Chain Reaction.

Authors:  Xianjing Zhang; Jun Guo; Bo Song; Feng Zhang
Journal:  ACS Omega       Date:  2022-09-07

5.  Early detection of viable Francisella tularensis in environmental matrices by culture-based PCR.

Authors:  Helen Y Buse; Brian J Morris; Eugene W Rice
Journal:  BMC Microbiol       Date:  2020-03-25       Impact factor: 3.605

6.  Determination of materials present in skeletonized human remains and the associated DNA: Development of a GC/MS protocol.

Authors:  Suni M Edson; Marcel Roberts
Journal:  Forensic Sci Int Synerg       Date:  2019-08-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.