Literature DB >> 26238528

A Micro-computed Tomographic Assessment of Root Canal Preparation with a Novel Instrument, TRUShape, in Mesial Roots of Mandibular Molars.

Ove A Peters1, Ana Arias2, Frank Paqué3.   

Abstract

INTRODUCTION: A novel S-shaped rotary file was developed to conform to nonround canal cross sections. However, the instrument should also perform well in small curved canals. This study used micro-computed tomographic scans to test the effects of TRUShape (Dentsply Tulsa Dental Specialties, Tulsa, OK) and a conventional rotary on canal geometry.
METHODS: Twenty mandibular molars with independent mesial canals were submitted to preoperative micro-computed tomographic scans (20-μm resolution). Canals were randomly allocated to 2 groups using Vortex (Dentsply Tulsa Dental Specialties) and TRUShape for shaping according to the directions for use. Scans were obtained after size 20/.06 and 30/.06; the following outcome variables were calculated: dentin volume, smallest radicular wall thickness, treated canal surface, canal transportation, and accumulated hard tissue debris. The number of preparation errors was tabulated; data were statistically contrasted using repeated measures and factorial analyses of variance.
RESULTS: The initial canal sizes were similar in both groups. Both instruments promoted preparation with no overt procedural errors. Vortex removed significantly more dentin both at size #20 and #30 (P < .02). Significantly (P < .02) more radicular wall dentin remained toward the furcation in the TRUShape group (1.02 ± 0.25 mm vs 0.94 ± 0.22 mm). The untreated surface at size #20 was 28.5 ± 13.9 and 19.4 ± 8.9 (P < .05), and it was 15.1 ± 8.5 and 11.3 ± 4.9 (P > .05) at size #30 for TRUShape and Vortex, respectively. Canal transportation at size #30 varied between 85 ± 57 μm and 179 ± 65 μm; the overall transportation scores were significantly lower for TRUShape (P < .05).
CONCLUSIONS: TRUShape provided conservation of dentin by limiting dentin removal and in the absence of substantial canal transportation. In the present study, the use of TRUShape in the mesial canals of mandibular molars did not result in decreased amounts of unprepared canal surface.
Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Keywords:  Canal transportation; dentin preservation; micro–computed tomographic imaging; untreated surface

Mesh:

Year:  2015        PMID: 26238528     DOI: 10.1016/j.joen.2015.06.007

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  19 in total

1.  Effect of root canal treatment procedures with a novel rotary nickel titanium instrument (TRUShape) on stress in mandibular molars: a comparative finite element analysis.

Authors:  Noemi Bonessio; Ana Arias; Guiseppe Lomiento; Ove A Peters
Journal:  Odontology       Date:  2016-02-05       Impact factor: 2.634

2.  Unprepared surface areas, accumulated hard tissue debris, and dentinal crack formation after preparation using reciprocating or rotary instruments: a study in human cadavers.

Authors:  Andrea F Campello; Marília F Marceliano-Alves; José F Siqueira; Simone C Fonseca; Ricardo T Lopes; Flávio R F Alves
Journal:  Clin Oral Investig       Date:  2021-04-26       Impact factor: 3.573

3.  Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

Authors:  Amr Elnaghy; Shaymaa Elsaka
Journal:  Clin Oral Investig       Date:  2017-10-13       Impact factor: 3.573

4.  Dual Rinse® HEDP increases the surface tension of NaOCl but may increase its dentin disinfection efficacy.

Authors:  Luciano Giardino; Massimo Del Fabbro; Marco Morra; Thais Pereira; Flaviana Bombarda de Andrade; Paolo Savadori; Luigi Generali
Journal:  Odontology       Date:  2019-06-13       Impact factor: 2.634

5.  Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems.

Authors:  Pelin Tufenkci; Kaan Orhan; Berkan Celikten; Burak Bilecenoglu; Gurkan Gur; Semra Sevimay
Journal:  Restor Dent Endod       Date:  2020-05-22

6.  Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties.

Authors:  Mehmet Emin Kaval; Ismail Davut Capar; Hüseyin Ertas; Bilge Hakan Sen
Journal:  Clin Oral Investig       Date:  2016-07-26       Impact factor: 3.573

7.  Working width, a deserted aspect of Endodontics.

Authors:  Denzil Albuquerque; Jojo Kottoor
Journal:  Restor Dent Endod       Date:  2015-09-23

8.  Micro-CT evaluation of apical delta morphologies in human teeth.

Authors:  Xianhua Gao; Franklin R Tay; James L Gutmann; Wei Fan; Ting Xu; Bing Fan
Journal:  Sci Rep       Date:  2016-11-07       Impact factor: 4.379

9.  Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography.

Authors:  Iussif Mamede-Neto; Alvaro Henrique Borges; Orlando Aguirre Guedes; Durvalino de Oliveira; Fábio Luis Miranda Pedro; Carlos Estrela
Journal:  Open Dent J       Date:  2017-02-14

10.  Multidimensional Analysis of Curved Root Canal Preparation Using Continuous or Reciprocating Nickel-titanium Instruments.

Authors:  Iussif Mamede-Neto; Álvaro Henrique Borges; Ana Helena Gonçalves Alencar; Marco Antonio Hungaro Duarte; Manoel Damião Sousa Neto; Carlos Estrela
Journal:  Open Dent J       Date:  2018-01-29
View more