Literature DB >> 26238160

Similar results for face mask versus mouthpiece during incremental exercise to exhaustion.

Dale R Wagner1, Nicolas W Clark1.   

Abstract

Investigations in the 1990s evaluated the influence of breathing assemblies on respiratory variables at rest and during exercise; however, research on new models of breathing assemblies is lacking. This study compared metabolic gas analysis data from a mouthpiece with a noseclip (MOUTH) and a face mask (MASK). Volunteers (7 males, 7 females; 25.1 ± 2.7 years) completed two maximal treadmill tests within 1 week, one MOUTH and one MASK, in random order. The difference in maximal oxygen consumption (VO2max) between MOUTH (52.7 ± 11.3 ml · kg(-1) · min(-1)) and MASK (52.2 ± 11.7 ml · kg(-1) · min(-1)) was not significant (P = 0.53). Likewise, the mean MOUTH-MASK differences in minute ventilation (VE), fraction of expired oxygen (FEO2) and carbon dioxide (FECO2), respiration rate (RR), tidal volume (Vt), heart rate (HR), and rating of perceived exertion (RPE) at maximal and submaximal intensities were not significant (P > 0.05). Furthermore, there was no systematic bias in the error scores (r = -0.13, P = 0.66), and 12 of the 14 participants had a VO2max difference of ≤3 ml · kg(-1) · min(-1) between conditions. Finally, there was no clear participant preference for using the MOUTH or MASK. Selection of MOUTH or MASK will not affect the participant's gas exchange or breathing patterns.

Entities:  

Keywords:  Aerobic capacity; VO2max; breathing apparatus; oxygen consumption; ventilation

Mesh:

Substances:

Year:  2015        PMID: 26238160     DOI: 10.1080/02640414.2015.1075058

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  4 in total

1.  Safety and feasibility of symptom-limited cardiopulmonary exercise test using the modified Naughton protocol in children with cerebral palsy: An observational study.

Authors:  Ah-Ran Kim; Min-Hwa Suk; Jeong-Yi Kwon
Journal:  Medicine (Baltimore)       Date:  2021-07-23       Impact factor: 1.817

2.  Effect of Test Interface on Respiratory Muscle Activity and Pulmonary Function During Respiratory Testing in Healthy Adults: A Pilot Study.

Authors:  Elaheh Sajjadi; Patrick C Mabe; Yasin B Seven; Barbara K Smith
Journal:  Cardiopulm Phys Ther J       Date:  2022-04

3.  Physiological Validation of an Airborne Ultrasound Based Surface Motion Camera for a Contactless Characterization of Breathing Pattern in Humans.

Authors:  Marie-Cécile Niérat; Pierantonio Laveneziana; Bruno-Pierre Dubé; Pavel Shirkovskiy; Ros-Kiri Ing; Thomas Similowski
Journal:  Front Physiol       Date:  2019-05-29       Impact factor: 4.566

4.  Measuring Ventilatory Activity with Structured Light Plethysmography (SLP) Reduces Instrumental Observer Effect and Preserves Tidal Breathing Variability in Healthy and COPD.

Authors:  Marie-Cécile Niérat; Bruno-Pierre Dubé; Claudia Llontop; Agnès Bellocq; Lila Layachi Ben Mohamed; Isabelle Rivals; Christian Straus; Thomas Similowski; Pierantonio Laveneziana
Journal:  Front Physiol       Date:  2017-05-18       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.