Two-year Randomized, Controlled Clinical Trial of a Flowable and Conventional Composite in Class I Restorations.

N C Lawson, R Radhakrishnan, D A Givan, L C Ramp, J O Burgess.   

Abstract

OBJECTIVES: This study evaluated the two-year clinical performance and volumetric wear of a flowable resin composite compared to a conventional highly filled composite resin in Class I restorations. METHODS AND MATERIALS: In this single-center, single-blinded, comparator-controlled clinical study (Institutional Review Board approved), 120 carious teeth distributed in 60 patients were randomly assigned to four calibrated practitioners who placed occlusal restorations (n=60 flowable and n=60 conventional composite). Direct and indirect assessment at baseline, six months, one year, and two years occurred during which the modified Cvar and Ryge criteria were evaluated. Volumetric wear was determined by superimposition of profilometer scans of baseline and two-year casts.
RESULTS: At two years, there was no significant difference in anatomic form (p=0.80), color match (p=0.08), marginal adaptation (p=0.89), marginal discoloration (p=0.79), surface integrity (p=0.18), secondary caries (p=0.66), cold sensitivity (p=0.522), occlusal sensitivity (p=0.818), or volumetric wear (p=0.661) between materials. Both materials showed a decrease in all criteria except secondary caries (p=0.95) over time. Two-year mean volumetric wear was 3.16 ± 2.38 mm(3) for the flowable composite and 3.43 ± 2.50 mm(3) for the conventional composite.
CONCLUSIONS: The flowable and conventional composites used in this study have similar clinical efficacy after two years of service when placed as Class I occlusal restorations having isthmus widths less than one-half the intercuspal distance.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26237643     DOI: 10.2341/15-038-C

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  10 in total

1.  Randomized controlled clinical trial of a highly filled flowable composite in non-carious cervical lesions: 3-year results.

Authors:  Haiying Zhang; Luxuan Wang; Lin Hua; Rui Guan; Benxiang Hou
Journal:  Clin Oral Investig       Date:  2021-04-02       Impact factor: 3.573

2.  Eight-year clinical evaluation of two types of resin composite in non-carious cervical lesions.

Authors:  Kei Kaida; Shisei Kubo; Takafumi Egoshi; Yohsuke Taira
Journal:  Clin Oral Investig       Date:  2022-06-25       Impact factor: 3.606

Review 3.  Compliance of randomized controlled trials in posterior restorations with the CONSORT statement: a systematic review of methodology.

Authors:  Márcia Rezende; Ana Cristina Rodrigues Martins; Jadson Araújo da Silva; Alessandra Reis; Juliana Larocca de Geus
Journal:  Clin Oral Investig       Date:  2021-09-30       Impact factor: 3.606

Review 4.  Clinical evaluation of flowable resin composite versus conventional resin composite in carious and noncarious lesions: Systematic review and meta-analysis.

Authors:  Omar Osama Shaalan; Eman Abou-Auf; Amira Farid El Zoghby
Journal:  J Conserv Dent       Date:  2017 Nov-Dec

5.  Clinical Evaluation of a Self-Adhering Flowable Resin Composite in Minimally Invasive Class I Cavities: 5-year Results of a Double Blind Randomized, Controlled Clinical Trial.

Authors:  Fatma Dilsad Oz; Esra Ergin; Filiz Yalcin Cakir; Sevil Gurgan
Journal:  Acta Stomatol Croat       Date:  2020-03

6.  Fracture Behavior of Short Fiber-Reinforced Direct Restorations in Large MOD Cavities.

Authors:  Márk Fráter; Tekla Sáry; Eszter Vincze-Bandi; András Volom; Gábor Braunitzer; Balázs Szabó P; Sufyan Garoushi; András Forster
Journal:  Polymers (Basel)       Date:  2021-06-23       Impact factor: 4.329

7.  Discoloration of different esthetic restorative materials: A spectrophotometric evaluation.

Authors:  Matteo Ceci; Matteo Viola; Davide Rattalino; Riccardo Beltrami; Marco Colombo; Claudio Poggio
Journal:  Eur J Dent       Date:  2017 Apr-Jun

Review 8.  Wear of resin composites: Current insights into underlying mechanisms, evaluation methods and influential factors.

Authors:  Akimasa Tsujimoto; Wayne W Barkmeier; Nicholas G Fischer; Kie Nojiri; Yuko Nagura; Toshiki Takamizawa; Mark A Latta; Masashi Miazaki
Journal:  Jpn Dent Sci Rev       Date:  2017-12-11

9.  Clinical evaluation of self-adhering flowable composite versus conventional flowable composite in conservative Class I cavities: Randomized controlled trial.

Authors:  Omar Osama Shaalan; Eman Abou-Auf; Amira Farid El Zoghby
Journal:  J Conserv Dent       Date:  2018 Sep-Oct

10.  A 24-Month Evaluation of Self-Adhering Flowable Composite Compared to Conventional Flowable Composite in Conservative Simple Occlusal Restorations: A Randomized Clinical Trial.

Authors:  Omar Osama Shaalan; Eman Abou-Auf
Journal:  Contemp Clin Dent       Date:  2021-12-21