Literature DB >> 26237424

Does patient-prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients?

Elena Sportelli1, Tommaso Regesta, Antonio Salsano, Paola Ghione, Carlotta Brega, Gian Paolo Bezante, Giancarlo Passerone, Francesco Santini.   

Abstract

BACKGROUND: To evaluate the impact of patient-prosthesis mismatch (PPM) on survival, functional status, and quality of life (QoL) after aortic valve replacement (AVR) with small prosthesis size in elderly patients.
METHODS: Between January 2005 and December 2013, 152 patients with pure aortic stenosis, aged at least 75 years, underwent AVR, with a 19 or 21 mm prosthetic heart valve. PPM was defined as an indexed effective orifice area less than 0.85 cm/m. Median age was 82 years (range 75-93 years). Mean follow-up was 56 months (range 1-82 months) and was 98% complete. Late survival rate, New York Heart Association functional class, and QoL (RAND SF-36) were assessed.
RESULTS: Overall, PPM was found in 78 patients (53.8%). Among them, 42 patients (29%) had an indexed effective orifice area less than 0.75 cm/m and 17 less than 0.65 cm/m (11.7%). Overall survival at 5 years was 78 ± 4.5% and was not influenced by PPM (P = NS). The mean New York Heart Association class for long-term survivors with PPM improved from 3.0 to 1.7 (P < 0.001). QoL (physical functioning 45.18 ± 11.35, energy/fatigue 49.36 ± 8.64, emotional well being 58.84 ± 15.44, social functioning 61.29 ± 6.15) was similar to that of no-PPM patients (P = NS).
CONCLUSION: PPM after AVR does not affect survival, functional status, and QoL in patients aged at least 75 years. Surgical procedures, often time-consuming, contemplated to prevent PPM, may therefore be not justified in this patient subgroup.

Entities:  

Mesh:

Year:  2016        PMID: 26237424     DOI: 10.2459/JCM.0000000000000292

Source DB:  PubMed          Journal:  J Cardiovasc Med (Hagerstown)        ISSN: 1558-2027            Impact factor:   2.160


  2 in total

1.  Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients.

Authors:  Abid Iqbal; Varghese Thomas Panicker; Jayakumar Karunakaran
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2018-08-28

2.  Impact of prosthesis-patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China.

Authors:  Lei Guo; Junnan Zheng; Liangwei Chen; Renyuan Li; Liang Ma; Yiming Ni; Haige Zhao
Journal:  J Cardiothorac Surg       Date:  2017-05-25       Impact factor: 1.637

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.