Volumetric x-ray coherent scatter imaging of cancer in resected breast tissue: a Monte Carlo study using virtual anthropomorphic phantoms.

Manu N Lakshmanan1, Brian P Harrawood, Ehsan Samei, Anuj J Kapadia.   

Abstract

Breast cancer patients undergoing surgery often choose to have a breast conserving surgery (BCS) instead of mastectomy for removal of only the breast tumor. If post-surgical analysis such as histological assessment of the resected tumor reveals insufficient healthy tissue margins around the cancerous tumor, the patient must undergo another surgery to remove the missed tumor tissue. Such re-excisions are reported to occur in 20%-70% of BCS patients. A real-time surgical margin assessment technique that is fast and consistently accurate could greatly reduce the number of re-excisions performed in BCS. We describe here a tumor margin assessment method based on x-ray coherent scatter computed tomography (CSCT) imaging and demonstrate its utility in surgical margin assessment using Monte Carlo simulations. A CSCT system was simulated in GEANT4 and used to simulate two virtual anthropomorphic CSCT scans of phantoms resembling surgically resected tissue. The resulting images were volume-rendered and found to distinguish cancerous tumors embedded in complex distributions of adipose and fibroglandular breast tissue (as is expected in the breast). The images exhibited sufficient spatial and spectral (i.e. momentum transfer) resolution to classify the tissue in any given voxel as healthy or cancerous. ROC analysis of the classification accuracy revealed an area under the curve of up to 0.97. These results indicate that coherent scatter imaging is promising as a possible fast and accurate surgical margin assessment technique.

Entities:  

Mesh:

Year:  2015        PMID: 26237265     DOI: 10.1088/0031-9155/60/16/6355

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Accuracy assessment and characterization of x-ray coded aperture coherent scatter spectral imaging for breast cancer classification.

Authors:  Manu N Lakshmanan; Joel A Greenberg; Ehsan Samei; Anuj J Kapadia
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-07

2.  Design and implementation of coded aperture coherent scatter spectral imaging of cancerous and healthy breast tissue samples.

Authors:  Manu N Lakshmanan; Joel A Greenberg; Ehsan Samei; Anuj J Kapadia
Journal:  J Med Imaging (Bellingham)       Date:  2016-02-16

3.  Coherent scatter imaging Monte Carlo simulation.

Authors:  Laila Hassan; Carolyn A MacDonald
Journal:  J Med Imaging (Bellingham)       Date:  2016-08-26

4.  X-ray fan beam coded aperture transmission and diffraction imaging for fast material analysis.

Authors:  Stefan Stryker; Joel A Greenberg; Shannon J McCall; Anuj J Kapadia
Journal:  Sci Rep       Date:  2021-05-19       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.