Literature DB >> 26235977

The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

Paul T Campbell1, Kevin R Kruse2, Christopher R Kroll2, Janet Y Patterson2, Michele J Esposito2.   

Abstract

BACKGROUND/
PURPOSE: Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System.
METHODS: Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively.
RESULTS: Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate.
CONCLUSIONS: Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Lesion measurement; Robotic PCI; Stenting

Mesh:

Year:  2015        PMID: 26235977     DOI: 10.1016/j.carrev.2015.06.005

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  7 in total

Review 1.  Cath Lab Robotics: Paradigm Change in Interventional Cardiology?

Authors:  Zachary K Wegermann; Rajesh V Swaminathan; Sunil V Rao
Journal:  Curr Cardiol Rep       Date:  2019-08-31       Impact factor: 2.931

Review 2.  Robotic-Assisted Percutaneous Coronary Intervention.

Authors:  Nathan Lo; Jorge Antonio Gutierrez; Rajesh V Swaminathan
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-02-24

3.  Current and Future Use of Robotic Devices to Perform Percutaneous Coronary Interventions: A Review.

Authors:  Elad Maor; Mackram F Eleid; Rajiv Gulati; Amir Lerman; Gurpreet S Sandhu
Journal:  J Am Heart Assoc       Date:  2017-07-24       Impact factor: 5.501

Review 4.  The Development of Robotic Technology in Cardiac and Vascular Interventions.

Authors:  Ali Pourdjabbar; Lawrence Ang; Ryan R Reeves; Mitul P Patel; Ehtisham Mahmud
Journal:  Rambam Maimonides Med J       Date:  2017-07-31

5.  Feasibility and safety of robotic PCI in China: first in man experience in Asia.

Authors:  Ke-Fei Dou; Chen-Xi Song; Chao-Wei Mu; Wei-Xian Yang; Cheng-Gang Zhu; Lei Feng; Jue Chen; Lei Song; Yu Ning; Bo Xu
Journal:  J Geriatr Cardiol       Date:  2019-05       Impact factor: 3.327

6.  First Experience of Robotic-assisted Percutaneous Coronary Intervention in Japan.

Authors:  Koutaro Kagiyama; Takafumi Ueno; Yoshiaki Mitsutake; Kazunori Yamaji; Takashi Ishimatsu; Ken-Ichiro Sasaki; Yoshihiro Fukumoto
Journal:  Intern Med       Date:  2019-07-31       Impact factor: 1.271

7.  First-in-Human Evaluation of the Safety and Efficacy of a Novel Stent Positioning Assistance System for Precise Positioning of Coronary Stents.

Authors:  Elias Hellou; Michael Jonas; Danny Dvir
Journal:  J Interv Cardiol       Date:  2022-03-27       Impact factor: 2.279

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.