Initial Acute Animal Experiment Using a New Miniature Axial Flow Pump in Series With the Natural Heart.

Eiji Okamoto1, Tetsuya Yano2, Yasuyuki Shiraishi3, Hidekazu Miura3, Tomoyuki Yambe3, Yoshinori Mitamura4.   

Abstract

We have advocated an axial flow blood pump called "valvo pump" that is implanted at the aortic valve position, and we have developed axial flow blood pumps to realize the concept of the valvo pump. The latest model of the axial flow blood pump mainly consists of a stator, a directly driven impeller, and a hydrodynamic bearing. The axial flow blood pump has a diameter of 33 mm and length of 74 mm, and the length of anatomical occupation is 33 mm. The axial flow blood pump is anastomosed to the aorta with polytetrafluoroethylene (PTFE) cuffs worn on the inflow and outflow ports. Dp-Q curves of the axial flow blood pump are flatter than those of ordinary axial flow pumps, and pump outflow of 5 L/min was obtained against a pressure difference of 50 mm Hg at a rotational speed of 9000 rpm in vitro. The axial flow blood pump was installed in a goat by anastomosing with the thoracic descending aorta using PTFE cuffs, and it was rotated at a rotational speed of 8000 rpm. Unlike in case of the ventricular assistance in parallel with the natural heart, pulsatilities of aortic pressure and aortic flow were preserved even when the pump was on, and mean aortic flow was increased by 1.5 L/min with increase in mean aortic pressure of 30 mm Hg. In conclusion, circulatory assistance in series with the natural heart using the axial flow blood pump was able to improve hemodynamic pulsatility, and it would contribute to improvement of end-organ circulation. .
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Artificial heart; Axial flow pump; Pulsatility; Ventricular assist device

Mesh:

Year:  2015        PMID: 26234449     DOI: 10.1111/aor.12558

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

Review 1.  Artificial hearts-recent progress: republication of the article published in the Japanese Journal of Artificial Organs.

Authors:  Masahiro Nishida
Journal:  J Artif Organs       Date:  2017-06-15       Impact factor: 1.731

2.  Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta.

Authors:  Eiji Okamoto; Tetsuya Yano; Hidekazu Miura; Yasuyuki Shiraishi; Tomoyuki Yambe; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2017-09-08       Impact factor: 1.731

3.  Computational Parametric Study of the Axial and Radial Clearances in a Centrifugal Rotary Blood Pump.

Authors:  Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Theodosios Korakianitis
Journal:  ASAIO J       Date:  2018 Sep/Oct       Impact factor: 2.872

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.