Literature DB >> 26231313

Referral system for hard exudates in eye fundus.

Syed Ali Gohar Naqvi1, Muhammad Faisal Zafar2, Ihsan ul Haq2.   

Abstract

Hard exudates are one of the most common anomalies/artifacts found in the eye fundus of patients suffering from diabetic retinopathy. These exudates are the major cause of loss of sight or blindness in people having diabetic retinopathy. Diagnosis of hard exudates requires considerable time and effort of an ophthalmologist. The ophthalmologists have become overloaded, so that there is a need for an automated diagnostic/referral system. In this paper a referral system for the hard exudates in the eye-fundus images has been presented. The proposed referral system works by combining different techniques like Scale Invariant Feature Transform (SIFT), K-means Clustering, Visual Dictionaries and Support Vector Machine (SVM). The system was also tested with Back Propagation Neural Network as a classifier. To test the performance of the system four fundus image databases were used. One publicly available image database was used to compare the performance of the system to the existing systems. To test the general performance of the system when the images are taken under different conditions and come from different sources, three other fundus image databases were mixed. The evaluation of the system was also performed on different sizes of the visual dictionaries. When using only one fundus image database the area under the curve (AUC) of maximum 0.9702 (97.02%) was achieved with accuracy of 95.02%. In case of mixed image databases an AUC of 0.9349 (93.49%) was recorded having accuracy of 87.23%. The results were compared to the existing systems and were found better/comparable.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Exudates; Eye fundus; Medical imaging; Treatment; Vision

Mesh:

Year:  2015        PMID: 26231313     DOI: 10.1016/j.compbiomed.2015.07.003

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  2 in total

1.  Hard exudates referral system in eye fundus utilizing speeded up robust features.

Authors:  Syed Ali Gohar Naqvi; Hafiz Muhammad Faisal Zafar; Ihsanul Haq
Journal:  Int J Ophthalmol       Date:  2017-07-18       Impact factor: 1.779

2.  Fundus images analysis using deep features for detection of exudates, hemorrhages and microaneurysms.

Authors:  Parham Khojasteh; Behzad Aliahmad; Dinesh K Kumar
Journal:  BMC Ophthalmol       Date:  2018-11-06       Impact factor: 2.209

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.