Literature DB >> 26225022

Treatment of Mandibular Fractures Using Intermaxillary Fixation and Vacuum Forming Splints: A Comparative Study.

D V Trupthi1, Shouvik Chowdhury2, Anjan Shah3, Madhumati Singh3.   

Abstract

OBJECTIVE: The study was done to compare the clinical efficacy of vacuum formed splints and arch bar in treating minimally displaced mandibular fractures.
METHOD: Forty patients were included in two groups. Group 1 was treated with custom made splints and group 2 with conventional arch bar. Patients were recalled on 3rd, 7th, 14th day and on the day of removal of the appliance. Periodontal status, stability of appliance and chair side time were evaluated.
RESULTS: The mean chair side time taken by vacuum formed splint was 18.05 min and conventional arch bar fixation was 68.25 min. 8.3 % of patients with vacuum formed splints had poor oral hygiene in comparison with 25 % of patients with conventional arch bar. 70 % of patients with vacuum formed splints and 60 % of the patients with conventional arch bars were comfortable in mastication during treatment.
CONCLUSION: Vacuum formed splints has better advantages over arch bar with respect to chair side time, periodontal health, patient's compliance of maintaining oral hygiene, mastication and speech. Vacuum formed splints avoid needle stick injuries. So, they can be used for intermaxillary fixation in minimally displaced mandibular fractures.

Entities:  

Keywords:  Arch bars; Intermaxillary fixation; Mandibular fractures; Vacuum formed splints

Year:  2013        PMID: 26225022      PMCID: PMC4518811          DOI: 10.1007/s12663-013-0573-9

Source DB:  PubMed          Journal:  J Maxillofac Oral Surg        ISSN: 0972-8270


  15 in total

1.  The pearl steel wire: a simplified appliance for maxillomandibular fixation.

Authors:  A Aldegheri; J L Blanc
Journal:  Br J Oral Maxillofac Surg       Date:  1999-04       Impact factor: 1.651

2.  Mandibular fractures: Historical perspective.

Authors:  R Mukerji; G Mukerji; M McGurk
Journal:  Br J Oral Maxillofac Surg       Date:  2005-08-19       Impact factor: 1.651

3.  The use of vacuum-formed splints for temporary intermaxillary fixation in the management of unilateral condylar fractures.

Authors:  T Lloyd; C Nightingale; R Edler
Journal:  Br J Oral Maxillofac Surg       Date:  2001-08       Impact factor: 1.651

4.  A new intermaxillary fixation method using adhesive cast splints for avoiding skin puncture.

Authors:  T Yamada; Y Sumi; Y Okazaki; M Ueda
Journal:  Aust Dent J       Date:  1998-06       Impact factor: 2.291

5.  The effect of interdental continuous loop wire splinting and intermaxillary fixation on the marginal gingiva.

Authors:  J L Lello; G E Lello
Journal:  Int J Oral Maxillofac Surg       Date:  1988-08       Impact factor: 2.789

6.  The use of orthodontic chain elastic for temporary intermaxillary fixation.

Authors:  A T Smith
Journal:  Br J Oral Maxillofac Surg       Date:  1993-08       Impact factor: 1.651

7.  Double gloving and a system for identifying glove perforations in maxillofacial trauma surgery.

Authors:  C M Avery; J Taylor; P A Johnson
Journal:  Br J Oral Maxillofac Surg       Date:  1999-08       Impact factor: 1.651

8.  Mandibular fractures: the problem patient.

Authors:  K Eid; D J Lynch; L A Whitaker
Journal:  J Trauma       Date:  1976-08

9.  Closed treatment of condylar fractures by intermaxillary fixation with thermoforming plates.

Authors:  Haruhiko Terai; Masashi Shimahara
Journal:  Br J Oral Maxillofac Surg       Date:  2004-02       Impact factor: 1.651

10.  Influence of arch bar splinting on periodontium and mobility of fixed teeth.

Authors:  K S Oikarinen; T M Nieminen
Journal:  Acta Odontol Scand       Date:  1994-08       Impact factor: 2.331

View more
  1 in total

1.  High-fluence low-power laser irradiation promotes odontogenesis and inflammation resolution in periodontitis by enhancing stem cell proliferation and differentiation.

Authors:  Tiejun Hou; Shanyong Li; Guangwei Zhang; Yan Li
Journal:  Int J Mol Med       Date:  2018-08-02       Impact factor: 4.101

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.